These types of motors are classified as dual voltage motors. The highest motor voltage rating is always double the lowest voltage rating. Dual voltage motors are more versatile in matching the system voltage supply that they are connected to. When the motor uses the highest voltage rating the coil legs are in series, dropping the high voltage across two coils. When the motor is connected to the low voltage rating the coils are connected in parallel dropping the low voltage rating across the two coils in parallel. As you can see no matter which configuration that you use the individual coils can never get a voltage across them greater than the lowest of the two voltages available. The connection diagram is usually on the underside of the motor's junction box lid.
To match 2 phase line voltage it has to be the same voltage.
The phase voltage is usually constant and determined by the supply voltage.
The phase angle between voltage and current in a purely resistive circuit is zero. Voltage and current are in phase with each other.
Don't know of any three phase low voltage motors. Perhaps it's a "stepper motor". Stepper motors are typically computer controlled, with the computer pulsing different pairs of wire to cause the motor to "step".
480 Volt
In a 3 phase system, the voltage measured between any two phase is called line to line voltage.And the voltage measured between line to neutral is called phase to neutral (line to neutral) voltage.AnswerThere is no such thing as a 'phase-to-phase' or a 'phase-to-neutral' voltage. The correct terms are 'line-to-line' and 'line-to-neutral'.The voltage between any two line conductors is called a line voltage.In a three-phase, three-wire, system, the line voltage is numerically equal to the phase voltage.In a three-phase, four-wire, system, the voltage between any line conductor and the neutral conductor is called a phase voltage. The line voltage is 1.732 times larger than the phase voltage.
Phase to Phase voltageCorrection to the above answer:There is no such thing as a 'phase-to-phase' or 'phase-to-ground' voltage. The correct terms are 'line-to-line' (or 'line voltage') and 'line-to-ground' (or 'phase voltage'). Transmission-line voltages are line-to-line (or 'line') voltages.
the voltage between 1 line & phase =120v The voltage between 2 line =240
Phase to phase voltage is 1.732 (the square root of 3) times the phase to star point (neutral) line voltage.e.g. if the line voltage is 220Vphase voltage = 1.732x220 = 380V (approx)Additional AnswerYou might also like to know that the line voltage leads the phase voltage by 30 electrical degrees. And, incidentally, the correct expressions are 'line-to-line' not 'phase-to-phase', and 'line-to-neutral' not 'phase-to-neutral' (think about it, a line voltage is measured from the junctions between adjacent phases, so they cannot be 'phase to phase'!)
There is phase to phase voltage in 3 phase system.AnswerYou don't get voltage 'phase-to-phase'; it's 'line-to-line'!
To answer this question a voltage must be stated.
In a wye system the voltage between any two wires will always give the same amount of voltage on a three phase system. However, the voltage between any one of the phase conductors (X1, X2, X3) and the neutral (X0) will be less than the power conductors. For example, if the voltage between the power conductors of any two phases of a three wire system is 220v, then the voltage from any phase conductor to ground will be 110v. This is due to the square root of three phase power. In a wye system, the voltage between any two power conductors will always be 1.732 (which is the square root of 3) times the voltage between the neutral and any one of the power phase conductors. The phase-to-ground voltage can be found by dividing the phase-to-phase voltage by 1.732 answer from ground and any phase