What are the differences between spt-1 and spt-2 cables and which one would be more suitable for my project?

SPT-1 cables are thinner and have a lower ampacity compared to SPT-2 cables, which are thicker and can handle higher currents. If your project requires higher power or longer distances, SPT-2 cables would be more suitable.


When was Blue Comet SPT Layzner created?

Blue Comet SPT Layzner was created on 1986-10-21.


Plural form of bridge?

Bridges is the plural form of bridge.


What is the difference between a half bridge and a full bridge inverter?

A half bridge inverter is an electronic circuit that uses different phases to do what it needs to do. A full bridge inverter is a single phase device so a half bridge is more complicated than a full bridge.


What is the difference between spt-1 and spt-2 wire?

spt-1, spt-2 & spt-3 wire difference: #3 has the thickest exterior .................................. The longer answer: spt-1, spt-2 & spt-3 = Stranded, Parallel, Thermoplastic (lamp cord) = "zip wire." It is the commonly-seen, flat, 2-conductor electrical cord found in most homes, with #18 gauge stranded copper wire inside. They connect table lamps, fans, clocks, extension cords, & Christmas lights. The difference between SPT-1, SPT-2 and SPT-3 rests with their protective exterior, each having heavier construction than the previous number. All are rated for a 7 amp load. Electricians like "zip cord" because the parallel wires can easily be snipped and pulled apart (unzipped) to quickly wire a plug or lamp. ---spt-3: is the newest cord , it has the thickest thermoplastic insulator, and has been the required size for most consumer electric items since the 1980's. ---spt-1: has the thinnest exterior and was introduced around the 1950's as the modern replacement for the twisted-pair cloth+rubber cords of the 1920's. Although spt-1 is still sold on spools, it has been gradually phased out for most consumer lighting because UL lab tests showed it prone to wear when people abused it (running under carpets, extreme abrasion, etc.). SPT-1 can still be found on many light-duty Christmas sets. .......... written by dave from austin, texas


What were the loyalist jobs?

to spt on the patriots


What is the advantage of using the bridge rectifier over the two diode form in the full wave rectification?

the ease of filtering their outpot voltages


What is the spt number?

That is the standard penetration test.


What is the phone number of the Cortland Regional Spt Council in Cortland New York?

The phone number of the Cortland Regional Spt Council is: 607-756-1864.