answersLogoWhite

0


Best Answer

Connection cords run through a conduit box so a to prevent accidental electrocution. Running the cords through the box ensures that the connections function properly and are protected as well.

User Avatar

Wiki User

10y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is the main function of conduit boxes?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

What is the main reason for connecting a ground wire to the end of a conduit being used to protect the wire?

== == Think about it. The conduit is metal, and can be touched by people. It is carrying live wires and is connected to steel junction boxes. What would happen if a hot wire accidentally touched the steel conduit? The ground wire is there to keep the conduit from going live in a fault condition. You want to ground any metal surface a user can touch in case of faults.


What is the maximum degrees bending for conduit?

its 180 degrees If you use the above answer the conduit will flatten and close off. The maximum degrees for a single bend in conduit is 90 degrees. Also code only allows four 90 degree bends in a conduit run between pull boxes.


What are the advantages and disadvantages of steel junction boxs?

There are no advantages or disadvantages over which type of junction box to be used on electrical wiring. As long as the junction box is of an approved type (CSA or UL approved). It is cost or location which dictates which boxes will be used. PVC boxes for home wiring are the cheapest. Aluminium or steel are usually used in rigid or EMT conduit systems. PVC again when the conduit system involves underground wiring. In large electrical installations it is the electrical engineer that states what the conduit system type is and what type of electrical junction boxes that must be used.


Do you have to break the ground wire at a pull box and bond it to the box?

When you refer to a pull box you have to be talking about a conduit system. In a metallic system, no don't have to ground pull boxes. By the fact that it is a metallic system the conduit and associated boxes are already grounded by the connection to the distribution panel. In a PVC conduit system a ground wire has to be pulled so that the load device has a return ground wire to trip the breaker on a ground fault. Pull boxes in a PVC system don't have to be grounded just the last junction box at the load.


What are some examples of a tee joint in the electrical trade?

A tee joint in the electrical trade is a conduit fitting. It is used in conduit work where there needs to be a device connected into the main conduit run. An example of this is where a light switch needs to be installed into the conduit run. The main conduit run starts at the distribution panel and proceeds to a lighting fixture. On the way a switch is needed to operate the light fixture. In the main conduit run a tee fitting is installed so as to pick up the switch for the fixture. When the conduit system is complete the wire is then drawn in. The "hot" conductor is pulled to the tee fitting and then diverts to the switch box to pick up the switch and then back up the same conduit to the tee fitting and then on to the lighting fixture. Splices are not usually made in tee fittings.

Related questions

What is the function of connectors?

The connectors are those things that exotic


What is the main reason for connecting a ground wire to the end of a conduit being used to protect the wire?

== == Think about it. The conduit is metal, and can be touched by people. It is carrying live wires and is connected to steel junction boxes. What would happen if a hot wire accidentally touched the steel conduit? The ground wire is there to keep the conduit from going live in a fault condition. You want to ground any metal surface a user can touch in case of faults.


What is the maximum degrees bending for conduit?

its 180 degrees If you use the above answer the conduit will flatten and close off. The maximum degrees for a single bend in conduit is 90 degrees. Also code only allows four 90 degree bends in a conduit run between pull boxes.


What combinations of bends in a conduit run require the use of a pull box?

Code states no more that 4 - 90 degree bends in a conduit run between pull boxes.


What are two main function of palnt stems?

To act as a conduit for sap and to hold the flowers upright.


What are the main principles concerning conduit bodies?

Conduit bodies are used to provide pulling access in a run of conduit, to conserve space where a full size bend radius would be impractical, to allow more bends to be made in a section of conduit or to split a conduit path into multiple directions.


What are the advantages and disadvantages of steel junction boxs?

There are no advantages or disadvantages over which type of junction box to be used on electrical wiring. As long as the junction box is of an approved type (CSA or UL approved). It is cost or location which dictates which boxes will be used. PVC boxes for home wiring are the cheapest. Aluminium or steel are usually used in rigid or EMT conduit systems. PVC again when the conduit system involves underground wiring. In large electrical installations it is the electrical engineer that states what the conduit system type is and what type of electrical junction boxes that must be used.


Do you have to break the ground wire at a pull box and bond it to the box?

When you refer to a pull box you have to be talking about a conduit system. In a metallic system, no don't have to ground pull boxes. By the fact that it is a metallic system the conduit and associated boxes are already grounded by the connection to the distribution panel. In a PVC conduit system a ground wire has to be pulled so that the load device has a return ground wire to trip the breaker on a ground fault. Pull boxes in a PVC system don't have to be grounded just the last junction box at the load.


What are some examples of a tee joint in the electrical trade?

A tee joint in the electrical trade is a conduit fitting. It is used in conduit work where there needs to be a device connected into the main conduit run. An example of this is where a light switch needs to be installed into the conduit run. The main conduit run starts at the distribution panel and proceeds to a lighting fixture. On the way a switch is needed to operate the light fixture. In the main conduit run a tee fitting is installed so as to pick up the switch for the fixture. When the conduit system is complete the wire is then drawn in. The "hot" conductor is pulled to the tee fitting and then diverts to the switch box to pick up the switch and then back up the same conduit to the tee fitting and then on to the lighting fixture. Splices are not usually made in tee fittings.


What is the main function of PC power supplies boxes?

The PC power supply box's function is to supply the computer with power. Without the PC power supply box, the computer would not be able to turn on and off.


Who are the main characters in the boxes?

PandoraZeusEpimetheus


What can one purchase at Westco?

One can purchase a variety of products from Westco some of them are: wire and cable, lighting, conduit and raceways, boxes and enclosures and wiring devices.