A circuit breaker is designed so that it will trip when the electric current is too high. That is the purpose of a circuit breaker. If there is a metal piece on the circuit breaker that prevents it from tripping, it is useless. Perhaps someone has altered it.

User Avatar

Wiki User

11y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is the metal piece on the circuit breaker preventing it from tripping?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Electrical Engineering

What is exactly the function of Neutral link in an electrical circuit?

To protect a circuit, we use a fuse or circuit breaker. The fuse or circuit breaker must always be placed in the lineconductor, never in the neutral conductor. So, if we want to completely isolate a circuit from the supply, we must remove the fuse from the line conductor, and open the link in the neutral conductor. A 'link' is a non-fusible metal break point in the neutral.


Can i use a circuit breaker with 420V nominal voltage in 520V line voltage nominal current of circuit breaker is 1600A if I can how much current can pass from this circuit breaker?

NO! NO! NO! The circuit breaker must be rated for the line voltage used. Exceeding this limit can cause catastrophic failure! If you are really working on a 1600A bus, stop right now, ang go hire a professional! Your question indicates you are not qualified to work on this gear. YOU ARE GOING TO KILL SOMEBODY. I'm not kidding about this. A breaker that is applied beyond its rating can arc over, and the resulting arc-flash can punch right through the panel cover, spraying vaporized metal on anyone unfortunate enough to be standing there. A 1600A bus can have a fault current of 20,000A OR MORE. This is not something to even think about working on unless you are trained and absolutely know what you are doing!


What is the name of a safety device that will shut off flow of electricity?

Devices used to open an electrical circuit are called OCPD's. (overcurrent protection devices) The most common are circuit breakers and fuses. In commercial motor starters they often employ another OCPD called a "heater" (UK thermal fuse) which is a metal strip which melts like the element in a small fuse when too much current (amps) go through it. They devices are in the circuit primarily to protect the wiring and devices they power. Circuit breakers such as in your home panel do protect you from a "shorted" circuit. Another safety and most common in residences are GFCI's or ground fault circuit interrupters (UK ELCB, Earth Leakage Circuit Breaker or RCD, Residual Current Detector) which come as both a receptacle (female plug) or as a circuit breaker.


What is a bare bright wire?

The bare wire is the equipment grounding conductor. Its purpose is to ground the metal parts of equipment that are not part of the circuit. This assures the proper function of the breaker in the event of a fault. It exists for your safety and disregarding it exposes you to potential danger, even death.


How can you confirm at the outlet with a meter if it truly is a 20A dedicated line and has not just had the outlet changed from 15A?

Any such attempt with a meter would just destroy the meter. Why not just find out which breaker/fuse controls the circuit and see what the breaker/fuse is rated at. Also find out what the wire size is. For a 20 AMP circuit you MUST have 12 gauge wire. There are other requirements but those two seem to be about the most significant. As has been stated, a meter won't help. The breaker prevents excessive load to be placed on the wiring so any 20 amp circuit would be limited by the breaker and there would be no other way to determine if a circuit is 15 Amp or 20 Amp other than to check at the breaker panel. Also, if someone just put a 20 amp breaker on a 14 gauge wire you have a serious fire hazard. As the above post suggests, have a professional check this out for you, it's too dangerous to make assumptions. Your description of "20A dedicated line" makes me think that you are needing a circuit for a heavy power-using-device that needs it own circuit (without any other receptacles or devices). If that is the case, then a meter can be used (with difficulty) to determine if any other outlets are connected to the same circuit. First turn off the power on the receptacle. Then check to see if any other receptacles are also dead. If so, they are probably on the same circuit and your receptacle is not a dedicated supply. Another method is to use a circuit tracer (available at Lowe's and other hardware and electrical supply stores). Plug the transmitter into the questionable receptacle, then use the receiver to check other receptacles to see if they are on the same circuit. Receptacles on the same circuit will cause a continuous fast beep (or other signal depending on model). You can also trace the circuit to the circuit breaker panel to find which breaker it is connected. It should be a 20-Ampere-trip breaker to make full use of a dedicated 20 A receptacle. Borrow an amp clamp and find the breaker in question. Clamp it around the neutral for that circuit (This takes a friend helping). Plug in a significant load like a hair dryer and have the friend turn in on and off while you watch the meter. It should read zero, then 8-10 amps then zero, etc. Plug loads in outlets that you think the contractor absconded the circuit from. The amps from those outlets should never show up on the amp clamp. Make sure the wire is 12 awg. A 12 awg wire will not push in the stabs of a 15 amp receptacle. SAFETY ADVICEBefore you do any work yourself,on household electricity supplies, equipment or appliances,always turn off the powerat the breaker box/fuse panel BEFORE you attempt to do any work ANDalways use an electrician's test meter having metal-tipped probes(not a simple proximity voltage indicator)to ensure the circuit is, in fact, de-energized. IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.

Related questions

How do circuit breakers apply to expansion?

A circuit breaker works by tripping a switch when too much current passes through it. As you may know, the higher the flow of energy, given a fixed resistance, the more heat will be generated. Because of this property, the heating of a metal strip (usually made from 2 different types of metals, so that it bends) is the mechanism for circuit discontinuation in a circuit breaker.


What are the devices contain in a circuit breaker?

The devices contained in a circuit breaker consist of a bi metal strip for over load protection and a small wrap of wire in the form of a coil for magnetic short circuit trip.


When dangerously high current flows through this overheated metal pushes the switch open to create an open circuit What is this?

A circuit breaker.


Where is the circuit breaker for the rear defog on 2003 Monte Carlo?

The circuit breaker is located on the back side of the fuse block that is located on the passenger side of the dashboard. you will have to release the clips that hold the fuse block down and turn it around. there you will find two metal box circuit breakers, one of which is the DEFOG breaker.


Can circuit breakers help to prevent building fires?

Breakers limit the current on the conductor to a safe level, too many appliances plugged in. You trip a breaker, hopefully you then transfer load to another circuit. Breakers use two different methods to accomplish this, one uses a bimetallic strip and the current passes directly through, too high a current causes the strip to deflect. It acts on a mechanism much like the sear in a guns trigger, the deflection pulls the trigger causing a spring to open the contacts and turn off the circuit. Another type is thermal magnetic, current passing through the breaker causes a magnetic field to act on a coil tripping the breaker. When breakers are wired and work properly they prevent fires!Bending metal opens a switch


What is air cicuit breaker?

Assuming you meant a not air. A circuit breaker is a device that prevents a circuit from overloading. When the current in a circuit reaches a predefined limit, the breaker trips and opens the circuit, stopping an overload. Commonly this is done using a strip of metal with one type of metal on one side and a different one on the other. The two metals have different coefficients of thermal expansion. When the current level is reached, the strip overheats. Because one metal expands more with heat the strip bends(high coefficient of thermal expansion on the convex side). This bending opens the circuit and prevents overload.


I have 25 metal halide lamps- 150 watt each with electronic ballast- a 10 amp MCB - but after two years this is tripping - these lamps are all on one circuit - what could be the cause and how to fix?

You have a total of 3750 watts on the circuit. The circuit amperage needs to be found but no voltage was stated. Use the following equation to find the amperage, I = W/E, Amps = Watts/Volts. Once the amperage is established then troubleshooting can commence. If the amperage is close to the threshold of the breaker then that might be a problem. One of the ballasts could be going to ground and drawing more current than the circuit breaker will allow. First find the circuit's amperage.


What component is constructed using a metal strip made of two different metals that will separate when current flow is excessive?

a circuit breaker


How does a circuit breaker operate?

A circuit breaker can be magnetic; the higher the current is the stronger the magnetic field will be, if the magnetic field gets strong enough it will pull open the circuit. A circuit breaker can also be thermal; as current travels through the circuit heat is generated (higher current = more heat), in the breaker there is two different kinds of metal bonded together, each will expand and contract at different rates, since they are bonded together they will bend and trip the circuit open. A circuit breaker can be a combination of magnetic and thermal.


Should a circuit breaker get hot on very hot days?

If a breaker isn't tripping, yet still feels quite warm, you probably are close to having too many appliances on its circuit. Breakers trip because of overloads (too many appliances), or shorts ( bare wires touching each other). These situations are quite dangerous and need to be corrected. If you can't find the problem, contact an electrician right away, and keep the circuit off.As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.


Where are Power windows circuit breaker dodge caravan?

On my 2003 I believe it is under the drivers side dash, right near the break padel. It has a plastic cover over it covering the metal cased breaker.


What is racking a circuit breaker?

Racking a ciruit breaker has no place in Home Electricity. It is a purely industrial or utility activity. It refers to the act of disconnecting an open (off) high voltage circuit breaker from both the electrical supply and the load by racking (winding, if you like) it out of an enclosure.Further AnswerRacking provides a method of isolating a high-voltage metal-clad circuit breaker (in the UK, typically 11 kV) from its supply and load circuits, and/or to provide earthing (grounding). Before racking, the circuit breaker must be opened, and this is usually ensured using an interlock system. Racking describes lowering a circuit breaker so that its bushings physically disconnect from fixed busbars/cables typically located above the circuit breaker. Once racked down, the circuit breaker can either be withdrawn to allow it to be maintained, or it can repositioned before being racked up to connect either the busbars or the cable to earth (ground).