A slope of 1/4" in 12' is 0.0017 - inadequate for cleansing; it should be at least 0.0084 to produce a reasonable flow velocity of 2 ft/sec.

The metric slope I was informed is 18mm in 1000mm

Most codes require a 1/4" slope for each 12" of run.

User Avatar

Wiki User

16y ago

What else can I help you with?

Continue Learning about Engineering

How do you fix the gradient of a sewer?

To fix the gradient of a sewer, first assess the current slope using a level or grading tool to determine areas where the gradient is insufficient or excessive. Next, excavate sections of the sewer as needed, either deepening or raising parts of the pipe to achieve the correct slope, typically a minimum of 1% (or 1/8 inch per foot) for proper drainage. Finally, backfill the trench carefully, ensuring that the new gradient is stable and properly aligned, and conduct a flow test to confirm that the adjustments effectively resolve any drainage issues.


What is the minimum required slope of asphaltic surface parking area?

Generally 1 in 300 is sufficient for parking space, but it can be variable depending upon the location/conditions of site


How to lay a 6'' sewer line at 1 percent grade?

sewer lines should never be laid at less than 1/4 " per foot and if there's absolutely no choice 1/8" per foot would work but I wouldn't advise it. just use a good spirit level and a measuring tape. Use the most slope you can without going too deep. Follow local plumbing codes.


How do you install underground drainage pipeline?

Installing underground drainage pipes involves digging a trench, laying the pipes, connecting them with fittings, and backfilling the trench. It's important to properly slope the pipes to ensure proper drainage and to use the right materials for the job. It's recommended to hire a professional for this type of installation.


What instrument measures slope?

Protractor or bevel gauge.

Related Questions

What is the minimum slope permitted for 2.5 inch underground sewer pipe?

It really depends on your local building code, but 2% should be the minimum so that your pipe will be self-cleaning.


What is the minimum slope for 110 mm diameter underground sewer pipe?

1/8" per foot


What is the minimum slope permitted for 8 inch underground sewer pipe?

1/16 PER IN PER FT. But the Fixture unit value decreases to only 1440 as opposed to 7300 at 1/2 Pitch.


What is the minimum slope for 6 inch underground sewer pipe?

1/4" per ft. is the lowest allowed. 1. Allowed by whom? Not many regulatory authorities specify the minimum slope of a 6" sewer pipe. 2. Why state in inches, typically engineers use a 2.0% or 0.02 / 100' form for the answer. 3. Using Manning's of 0.013 (although most PVC could use a 0.009 or 0.011 n factor, you can achieve the 2 ft/sec typical requirement with a slope of 0.005 or 0.5%, although it was stated to me that 0.0067 or 0.67% is the correct minimun slope to use. I am just trying to find that source which is tough as most authorities do not specify the minimum slope of a 6" pipe.


What is minimum asphalt paving slope?

The minimum slope shall be 1% to 2%.


What is the slope of a 4 sewer pipe?

1/4 " per ft is average


Should there be standing water in the sewer pipe to the street?

No, there shouldn't be any standing water in a sewer line, this is what creates bad bacteria and disease. All waste needs to go down a sewer line and disappear ito the street sewer line. If this is the case, either you have a slight blockage or the sewer line gradient is incorrect. The correct ratio for the gradint of a sewer line must be 1:40 (meters) simpler measurement for slope is 1/4" per foot(ideal). absolute minimum 1/8" per foot(not recommended except where not avoidable)


What is the maximum slope for 4 inch sewer pipe?

1/8th per inch


How do you calculate the slope on a sewer line 320 feet long?

320*.25=8 inches


What is the slope for airport underground baggage ramp?

Some slopes for airport underground baggage ramps can be as steep as 90 degrees. The slope is necessary to both save space and facilitate the travel of the baggage to the underground area to be sorted.


How much slope on concrete patio around a underground pool?

Try to do as little as possible of a slope, so you won't feel it but so it has a slope


How much slope for a 200' sewer run?

For a 200-foot sewer run, a common slope recommendation is 1% to 2% (or 1/8 inch to 1/4 inch per foot). This translates to a total drop of 2 to 4 inches over the entire length. The specific slope may vary based on local codes and the type of sewer system, so it's essential to consult local regulations for precise requirements.