1/16 PER IN PER FT. But the Fixture unit value decreases to only 1440 as opposed to 7300 at 1/2 Pitch.
It really depends on your local building code, but 2% should be the minimum so that your pipe will be self-cleaning.
1/8" per foot
A slope of 1/4" in 12' is 0.0017 - inadequate for cleansing; it should be at least 0.0084 to produce a reasonable flow velocity of 2 ft/sec. The metric slope I was informed is 18mm in 1000mm Most codes require a 1/4" slope for each 12" of run.
1/4" per ft. is the lowest allowed. 1. Allowed by whom? Not many regulatory authorities specify the minimum slope of a 6" sewer pipe. 2. Why state in inches, typically engineers use a 2.0% or 0.02 / 100' form for the answer. 3. Using Manning's of 0.013 (although most PVC could use a 0.009 or 0.011 n factor, you can achieve the 2 ft/sec typical requirement with a slope of 0.005 or 0.5%, although it was stated to me that 0.0067 or 0.67% is the correct minimun slope to use. I am just trying to find that source which is tough as most authorities do not specify the minimum slope of a 6" pipe.
The minimum slope shall be 1% to 2%.
For sanitary sewer lines in commercial buildings, the minimum slope depends on the pipe diameter, as set by plumbing codes like the International Plumbing Code (IPC) or Uniform Plumbing Code (UPC): Pipes 2.5 inches (65 mm) or smaller: minimum slope is 1/4 inch per foot (≈ 2.08%). Pipes 3 inches (75 mm) to 6 inches (150 mm): minimum slope is 1/8 inch per foot (≈ 1.04%). Larger pipes (8 inches / 200 mm or more): slope can be 1/16 inch per foot (≈ 0.5%), if allowed by design and code. This slope ensures wastewater flows fast enough to prevent clogs but not too fast to leave solids behind.
1/4 " per ft is average
No, there shouldn't be any standing water in a sewer line, this is what creates bad bacteria and disease. All waste needs to go down a sewer line and disappear ito the street sewer line. If this is the case, either you have a slight blockage or the sewer line gradient is incorrect. The correct ratio for the gradint of a sewer line must be 1:40 (meters) simpler measurement for slope is 1/4" per foot(ideal). absolute minimum 1/8" per foot(not recommended except where not avoidable)
1/8th per inch
To fix the gradient of a sewer, first assess the current slope using a level or grading tool to determine areas where the gradient is insufficient or excessive. Next, excavate sections of the sewer as needed, either deepening or raising parts of the pipe to achieve the correct slope, typically a minimum of 1% (or 1/8 inch per foot) for proper drainage. Finally, backfill the trench carefully, ensuring that the new gradient is stable and properly aligned, and conduct a flow test to confirm that the adjustments effectively resolve any drainage issues.
320*.25=8 inches