according to electrical code, a maximum on 12 outlets on a branch circuit unless the loads are known.
30 amps
No, a double pole 50 amp breaker protects a 240 volt supply at 50 amps. The number that is on the handle of the breaker is the amperage that the breaker will trip at if an overload occurs on the circuit.
A 15 amp circuit breaker will handle this situation very well. The smallest home breaker is rated at 15 amp.
If the overcurrent protection device is 40 Amps, then a 30-Amp plug can overheat and catch fire at 40 Amps before the circuit-breaker blows.
There isn't a formula, but the general rule is that you allow for 1 amp per outlet and you load the circuit to 80% of maximum. For a 15 Amp circuit you can have a maximum of 12 outlets.
30 amps
No, a double pole 50 amp breaker protects a 240 volt supply at 50 amps. The number that is on the handle of the breaker is the amperage that the breaker will trip at if an overload occurs on the circuit.
A 15 amp circuit breaker will handle this situation very well. The smallest home breaker is rated at 15 amp.
If the overcurrent protection device is 40 Amps, then a 30-Amp plug can overheat and catch fire at 40 Amps before the circuit-breaker blows.
There isn't a formula, but the general rule is that you allow for 1 amp per outlet and you load the circuit to 80% of maximum. For a 15 Amp circuit you can have a maximum of 12 outlets.
It sounds to me like the exhaust timer is just a switch. The 20 amp rating that the timer is given is the maximum amount of current that it can handle and still be within its safety specifications. It will work very well on a 15 amp circuit.
See discuss question below.
circuit #12 30 amp
industry standard practice. the electrical load from a combination range is the same as the combined loads from a wall oven and countertop. so your panel and electric service will handle it. BUT the range will be on a single circuit and you must ensure that the range circuit requirements are met. the circuit requirements are on the nameplate. for example, if the range requires a 30 amp circuit and your wall oven was a 30 amp circuit then you can use the wall oven circuit. but if the range requires a 40 amp circuit, then you have to pull a 40 amp circuit from the panel to the range.
No. A 120 volt 15 amp service will handle a maximum of 1,800 watts. Even a 20 amp service will only handle 2400 watts and that is at max load which you should never load on a 20 amp circuit. You will need a 30 amp 120 volt or 240 volt service for 2400 watts.
2.3 kw per hour on a 110-120 volt circuit.
If you have 100 amp wire, you can use it for a 60 amp circuit, or for any circuit of 100 amps or less. But if you have a 60 amp circuit, 60 amp wire is thinner and cheaper than 100 amp wire.