This is the current flowing in the primary circuit when full-load current flows in the secondary circuit.
Because some of the primary flux fails to link with its own winding, the back- e.m.f. induced into the primary winding will be slightly lower than it would be had there been no leakage at all. We can account for this 'loss' of induced voltage as though it were caused by a small voltage drop occurring in the primary circuit, due to a small inductive-reactance connected in series with the primary winding. We call this the 'primary leakage reactance' (Xp).A similar explanation can be applied to the secondary circuit, thus giving the secondary circuit a 'secondary leakage reactance' (Xs).
Signal Loss and Bandwidth
A secondary current of 0 would suggest to me that the secondary circuit is open. A normally operating circuit with zero current flow would be very unusual. No load in secondary circuit. No secondary current can also be attributed to the primary power source open or an open primary winding.
Generally speaking, equivalent circuits are used to simplify a complex circuit into terms that are solvable with known relations. For example, in a transformer equivalent circuit you can account for winding losses and flux leakage with a series resistance and reactance on the primary side. Core losses can be modeled similarly with a parallel resistance and reactance on the primary also. Essentially when reflecting/referring an impedance to the primary side of a transformer, you are just seeing what the secondary impedance "looks like" to the primary side. Since the secondary impedance will determine the load on the primary, it is helpful to know how to relate it in terms of the primary so as to calculate the current flow in the primary due to the load on the secondary.
The secondary need to continue and help the primary one.
T-1
Yes. The designation as primary residence is irrelevant to the number of mortgages.
This is the current flowing in the primary circuit when full-load current flows in the secondary circuit.
To limit the current flowing through the primary circuit.
To electrically isolate the secondary circuit from the primary circuit, without changing the voltage.
No ; False
The terms 'primary', 'secondary', and 'tertiary' winding has absolutely nothing whatsoever to do with voltage levels. The primary winding is simply that winding connected to the supply, while the secondary winding is that winding connected to the load. The voltages of these windings depend on whether you are dealing with a step-up or step-down transformer.
Mechanical pressure from the primary piston
Mechanical pressure from the primary piston
There is no disadvantage with a current transformer -it does exactly what it's supposed to do, that is:reduce the current flowing in the primary circuit to a value that can be handled by its burden (ammeter or protective relay).electrically-isolate its secondary circuit from the primary circuit.