answersLogoWhite

0

To provide a low-resistance return in the event of a earth-fault current occurring anywhere in the circuit. The requirement for a low-resistance return is to ensure the resulting fault current causes the relevant protective device to disconnect the faulty circuit.

User Avatar

Wiki User

13y ago

What else can I help you with?

Related Questions

What is the connection between any electrical circuit and the earth is called?

Electrical circuits are grounded to the earth.


Can electric circuit b completed without earth?

Yes, an electric circuit can be completed without connecting it to earth. The circuit needs a complete path for the current to flow back to the source, so as long as the circuit is properly connected and the electrons can flow through the components, it will work without needing an earth connection.


How do you test for earth in a lighting circuit?

To test for earth in a lighting circuit, you can use a multimeter set to measure resistance or continuity. First, ensure the circuit is turned off and isolate the lighting circuit from the power supply. Then, connect one probe of the multimeter to the earth terminal and the other probe to a known earth point, such as a metal part of the fixture or an earth rod. A low resistance reading indicates a good earth connection, while a high or infinite reading suggests a problem with the earthing.


How did you check the electical resistance of the headlight earth connection?

Ohmeter connected both ends ground circuit. Usually this circuit very short with minimal resistance due to that. Do you have a good solid ground?


What is purpose of the Earth wiring?

When there is too much current flowing through a circuit the earth wire will take the current away and prevent someone from getting an electric shock


Explain what a circuit main earth does?

Basically, it's an earth connection applied for the purpose of making apparatus safe to work on before a Permit to Work or Sanction for Test is issued. Disconnect from power, test dead, apply CME.


If a circuit needs a round trip to work how does a telegraph work on a single wire?

The return path is through the Earth. That's called the "ground" connection.


Why earth wire is green and yellow stripped colour?

The green and yellow striped color of the earth wire is an international standard to easily identify it as the connection for grounding in electrical systems. This color scheme helps to prevent confusion and ensures safety by providing a clear indication of the purpose of the wire.


Why it is necessary to have an earth wire installed in a power circuit but not in a lighting circuit?

Power circuit carries high power and costly devices. If there is some unwanted power signal(noise) in the wire it can damage the device. To reduce this effect earth is necessary.Lighting circuit carries low power(current).So, we ignore the earth terminal.Answer for UKLighting cables do normally include a protective (earth) conductor, and this is terminated in each ceiling rose, as are the line and neutral conductors. Whether or not the earth terminal is actually then used depends on the luminaire (light fitting). For example, if it is simply a suspended lamp then the earth connection is not used; on the other hand, if it is a fluorescent lamp enclosed in a metal enclosure, then the enclosure is connected to the earth terminal.


How could an improper electrical earthing connection affect an appliance?

In a properly operating appliance, there is no connection between any of its internal wiring and its chassis and/or its metal case, if there is one. As such, the earthing connection being improper will not affect the operation of the appliance.However, and this is critical, an improper earthing connection can present an electrocution hazard to the user...If the earth connection were electrically live or "hot", for instance, then the chassis of the appliance would also become live or "hot". Touching it, along with a real earth connection such as a water faucet, could cause electrocution.Additionally, if the earth connection is simply missing, then an internal malfunction within the appliance could cause the chassis and/or its metal case, if there is one, to become live or "hot", creating the same risk of electrocution.The purpose of the earthing connection is - in the event of appliance malfunction - to cause a high enough fault current that will force the protective device (fuse or circuit breaker) to trip and break the supply of current to the appliance.


Why the high resistance earth fault in the appliance increase the risk of electric shock when using appliance in earth situation?

If the earth connection has a high resistance it is not capable of acting as a true earth. For example, the high resistance might mean that the fuse or circuit-breaker will fail to operate when there is a fault.


What is earth day purpose?

the purpose for earth day is to help save the earth