What tank?
assume that the air is originally at atmospheric pressure
residual air pressure in the tank, and the pressure switch settings
I believe that your pressure tank is "waterlogged", meaning, there is very little if any air trapped at the top of the pressure tank. A simple solution is to shut off the supply to the tank. Then completely drain the tank. And, finally, refilling the tank which will trap a sufficient amount of air, which will compress under pressure, allowing your system to have a larger operating pressure range. Good Luck.
If you mean a well tank, the water is forced in by the pump. The residual air pressure pushes the water out to the faucets.
The air charge in a bladder tank should be 2 PSI below the pressure switch ON setting. In other words if the pressure switch is a 30-50, then the tank air should be 28. -If the pressure switch is the higher 40-60, then the tank air is 38. These tanks are all charged at the top and you can check air pressure there also.
A bubbling noise in a well pressure tank is a sign of a hole in the tank. It means that air is getting into the tank and causing air to bubble through the water.
The water pressure depends on the residual air pressure in the tank. Normally it should be between 30 -50-psi. Tank air pressure is important, it should be about 27-29 when water is nearly empty.
The pump will switch on frequently. This indicates lack of air in the pressure tank which is the most common problemThe pump will switch on frequently. This indicates lack of air in the pressure tank which is the most common problem
A pressure foot is used to measure air pressure inside a tank. This means that every square foot of the tank, there is a pound of pressure.
The pressure in your tank should be checked with water drained from the tank, with the water drained the air pressure in the tank should be set 2psi lower than your kick in pressure. So for a kick in pressure of 25psi the tank air pressure should be set at 23psi.Ans 2 - Water should NOT be totally drained from the tank or you may get a false reading ! - Leave 2-3 gallons in the tank. Most systems have the pressure switch set at 30 Psi, so tank residual pressure should be 28psi. - Lower than this gives really dismal pressure in the shower, especially if it's on second floor.
25436546
This is done at the pressure tank. First drain the tank with pump off, then check air pressure at the tank top nipple. It should be above 26 psi. If not this is your problem. You may need a new tank or it it's a 'galvanised ' tank , a new air charge. You may also need the pressure switch adjusted, or even a new one. -Call a well technician for an expert opinion and repair.This is done at the pressure tank. First drain the tank with pump off, then check air pressure at the tank top nipple. It should be above 26 psi. If not this is your problem. You may need a new tank or it it's a 'galvanised ' tank , a new air charge. You may also need the pressure switch adjusted,or even a new one.-Call a well technician.