Power factor is the ratio of apparent versus true power. It depends on the phase angle between voltage and current, and is the cosine of that phase angle.

This occurs because a motor is an inductive (reactive) load, constituting a stored energy device. In an inductor, current lags voltage. In a capacitor, current leads voltage.

User Avatar

Wiki User

13y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is the relationship between motor speed and power factor?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

Where would power factor capacitors be installed on a 3 phase motor?

Power factor capacitors can be installed on a three phase motor between the motor contactor and the overload heater block.


What is the power factor of an induction motor?

Induction motor comprised inductor as the most part in it and an inductor has the characteristic to oppose the change of current, i.e., it has lagging power factor as current lags behind the voltage. Hence, an induction motor works on lagging power factor.


What is the difference between unity power factor to 8 power factor?

Power factor does not go above 1. It is the cosine of the phase angle between voltage and current and, as such, can range between +1 and -1, although it should be understood that a negative power factor is mathematically equivalent to a generator - when looking at the load as if it is a motor - or vice versa. Unity power factor is applicable for a resistive load. A typical power factor for a big motor is about 0.92. A theoretical power factor of zero, corresponding to a phase angle of 90 degrees, would mean that the load is purely inductive or capacitive, and that the power supply and conductors are also ideal or theoretical.


How you improve power factor in synchronous motor?

Power Factor measures the difference in phase between the current and voltage. When they are in phase the Power Factor is defined as 1. When out of phase the value is less than 1. If they are 180 degrees out of phase the Power Factor will be zero.


When you should use synchronous motor instead of capacitor for power factor correction?

Synchronous motors show some interesting properties, which finds applications in power factor correction. The synchronous motor can be run at lagging, unity or leading power factor. The control is with the field excitation, as described below:When the field excitation voltage is decreased, the motor runs in lagging power factor. The power factor by which the motor lags varies directly with the drop in excitation voltage. This condition is called under-excitation.When the field excitation voltage is made equal to the rated voltage, the motor runs at unity power factor.When the field excitation voltage is increased above the rated voltage, the motor runs at leading power factor. And the power factor by which the motor leads varies directly with the increase in field excitation voltage. This condition is called over-excitation.The most basic property of sycho motor is that it can be use as a CAPACITOR OR INDUCTOR both. Hence in turn it improves the power factor of system.The leading power factor operation of synchronous motor finds application in power factor correction. Normally, all the loads connected to the power supply grid run in lagging power factor, which increases reactive power consumption in the grid, thus contributing to additional losses. In such cases, a synchronous motor with no load is connected to the grid and is run over-excited, so that the leading power factor created by synchronous motor compensates the existing lagging power factor in the grid and the overall power factor is brought close to 1 (unity power factor). If unity power factor is maintained in a grid, reactive power losses diminish to zero, increasing the efficiency of the grid. This operation of synchronous motor in over-excited mode to correct the power factor is sometimes called as Synchronous_condenser.

Related questions

Where would power factor capacitors be installed on a 3 phase motor?

Power factor capacitors can be installed on a three phase motor between the motor contactor and the overload heater block.


What is the Relation between power factor and slip?

inversely proportional relationship


What is the power factor of an induction motor?

Induction motor comprised inductor as the most part in it and an inductor has the characteristic to oppose the change of current, i.e., it has lagging power factor as current lags behind the voltage. Hence, an induction motor works on lagging power factor.


What is the difference between unity power factor to 8 power factor?

Power factor does not go above 1. It is the cosine of the phase angle between voltage and current and, as such, can range between +1 and -1, although it should be understood that a negative power factor is mathematically equivalent to a generator - when looking at the load as if it is a motor - or vice versa. Unity power factor is applicable for a resistive load. A typical power factor for a big motor is about 0.92. A theoretical power factor of zero, corresponding to a phase angle of 90 degrees, would mean that the load is purely inductive or capacitive, and that the power supply and conductors are also ideal or theoretical.


What is the effect of induction motor on power factor?

An induction motor has a lagging power factor. Motors of more than about 2 HP are designed to have a power factor of 0.85 or higher.


How you improve power factor in synchronous motor?

Power Factor measures the difference in phase between the current and voltage. When they are in phase the Power Factor is defined as 1. When out of phase the value is less than 1. If they are 180 degrees out of phase the Power Factor will be zero.


When you should use synchronous motor instead of capacitor for power factor correction?

Synchronous motors show some interesting properties, which finds applications in power factor correction. The synchronous motor can be run at lagging, unity or leading power factor. The control is with the field excitation, as described below:When the field excitation voltage is decreased, the motor runs in lagging power factor. The power factor by which the motor lags varies directly with the drop in excitation voltage. This condition is called under-excitation.When the field excitation voltage is made equal to the rated voltage, the motor runs at unity power factor.When the field excitation voltage is increased above the rated voltage, the motor runs at leading power factor. And the power factor by which the motor leads varies directly with the increase in field excitation voltage. This condition is called over-excitation.The most basic property of sycho motor is that it can be use as a CAPACITOR OR INDUCTOR both. Hence in turn it improves the power factor of system.The leading power factor operation of synchronous motor finds application in power factor correction. Normally, all the loads connected to the power supply grid run in lagging power factor, which increases reactive power consumption in the grid, thus contributing to additional losses. In such cases, a synchronous motor with no load is connected to the grid and is run over-excited, so that the leading power factor created by synchronous motor compensates the existing lagging power factor in the grid and the overall power factor is brought close to 1 (unity power factor). If unity power factor is maintained in a grid, reactive power losses diminish to zero, increasing the efficiency of the grid. This operation of synchronous motor in over-excited mode to correct the power factor is sometimes called as Synchronous_condenser.


What is cos on an electric motor?

Cos phi is a European term used on a motor to differentiate between apparent power (kVA) of an inductive load as compared to the active power (kW) that is really used by the load. Cos phi= active power/apparent power. In North America a more familiar term would be power factor. Power factor = kW/kVA


What is the Relationship between power factor and current?

When voltage and current waveforms are out of synch the power factor is reduced. In a pure resistance load the PF is 1. When inductance and capacitance is involved the PF is from 0 to 1.


How does reactive power change the Power Factor?

Power Factor is the relationship between the phase of the current and voltage which are each sine waves. When there is an inductance in a circuit the AC current waveform tends to lag the voltage. This causes a phase difference which reduces the Power Factor from a maximum of one to something less.


When is the power factor of a motor 1?

When the circuit is purely resistive or in resonance, i.e. capacitive and inductive reactance cancels out.Power factor is the ratio of apparent power over true power, and is the cosine of the phase angle between voltage and current.


When a load on a normally excited synchronous motor is increased its power factor tends to?

power factor normally goes to the lagging