A 225 amp load will physically not be able to tie into a 15 amp breaker and a duplex receptacle as you can not get a 3/0 wire under the breaker and receptacle terminal screws.
Yes but there are two stipulations, one that the join or splice must be made in a junction box that is accessible and has a removable cover and the second stipulation is that the breaker that is supplying the power can not be larger that the smallest conductor. In this case no breaker larger that a 20 amp breaker as #12 wire is only rated at 20 amps.
The breaker will trip at the amperage notated on the breaker. If it's 100A...it will trip at or around 100A. It does not matter if that breaker is physically tied to another 100A breaker. To understand this, imagine that you remove the mechanical tie from the two-pole breaker. Now you just have two 100A breakers. In actuality, you always had two 100A breakers. The mechanical tie does not change that. If you then powered two, separate 120 volt devices from the two breakers, each breaker would allow 100 amperes to pass to each of the devices before tripping. So why are they tied together? That is done when the two-pole breaker is to be used to power a 240 volt circuit. In AC current, electricity flows in both directions. In a 120 volt circuit, it flows "out" toward the device via the hot (generally the black wire) and "back" via the neutral (generally the white wire). Then the cycle reverses. It does this 60 times per second (60Hz). The amperage in the hot and neutral wires are the same (in the perfect world). Only the hot wire is connected to the breaker. In a 240 volt circuit, there is no neutral wire. You are using two "legs" of 120 volts each that are 180 degrees out of phase with each other. In other words, as leg 1 is flowing "out", leg 2 is flowing "back". Because they are out of phase, the potential difference is twice the voltage of each line or 240 volts. The current flows out and back at the same 60 Hz but this time via the two hot wires (generally black and red). Each of these hot wires are connected to the two terminals of the two-pole breaker. Due to mechanical tolerances, one breaker will most likely trip before the other. Therefore, if the rated current, (100 amps), is exceeded on either breaker, that breaker will trip and the other breaker will trip via the mechanical tie. This ensures that all power to the outlet is disconnected. If you removed the tie and only one breaker tripped, there would still be 120 volts connected to the outlet. In summary, each leg of a single, double (2 phase) or triple (3 phase) breaker is capable of allowing the amount of current denoted on the breaker. The connected circuit, regardless of voltage is protected from exceeding that amperage.
Yes, as long as the splice is made in a junction box that can have a cover attached to it and it must be accessable. This means its not to be covered with drywall. The wire must also be of the correct size and conductor count. For a dryer it is a 3 conductor #10 wire. The breaker size at the breaker panel is a two pole 30 amp.
Yes, bow ties are harder to tie than regular ties. If one checks different websites and videos that provide tutorials of how to tie a tie/bow tie, the level of difficulty of tying bow ties is always rated much higher.
Tie breaker
The outcomes for each set is not independent. For a set to go into a tie breaker the players need to be very evenly matched. If they are, there is a greater probability that the sets will go into tie breaker. If you disregard that aspect of realitythen the answer is 0.0270, approx.
No
Chicago won the tie breaker game for the 2008 AL Central Division championship by the score of 1-0.
at the end of a game when the game is tied
Tie games are usually decided by penalty kick shootouts.
Multiple ties require calculation to establish final positioning. In basketball the triple tie breaker requires adding up the teams scores to determine final rank.
a tie breaker!
three teams have 1loss and 1 win ,how to do computation for triple tie breaker quotient system
no
After tine has ran out and u are still tied.
In 2009 the Minnesota Twins and the Detroit Tigers played a tie breaker which the Twins won.