Q: What is used in tightening high pressure piping installation?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Types of piping?

piping critical , non critical critical piping : where temperature ,pressure are high and sizes of pipe are big and piping connected to critical equipment( such pump,turbine compressor etc) non critical : other than criti


What causes high water pressure in the first faucet on the water line from where it enters the house. The cold water is under high pressure but other faucets in house are fine.?

Possibly a pressure reducing valve installed after piping for first faucet, which would cause situation describing.


Why very high pressure piping are made of stemless pipe smooth surfaces?

This question is poorly worded. Clean up the English so it is legible and understandable.


What is weldolet in pipe fittings?

Weldolet is used for Butt weld branch connection where standard tee is not available due to size restrictions and the piping is of critical / high pressure service.


Is abs acceptable to use when re-piping under a kitchen sink in a high rise building?

As long as new abs piping is connected to existing piping within code.


Why did your sump pump stop working?

1- Thermo overload=2- Pumping against too high a head (static pressure) cause by excessive piping or a partial stoppage or undersized piping or to many restrictions such as short radius ells or a bad check valve==3- float not properly set=


What is the difference between PE80 AND PE100?

from : Engineeringtoolbox.comPolyethylene pipes are also classified by the type of material used:PE 32 - low pressure piping systemsPE 40 - low pressure piping systemsPE 63 - medium pressure piping systems - irrigation system - drinking water connectionsPE 80 - gas pipe for natural gas distribution network with pressure rate up to 4 bars - drinking water pipe with pressure rate up to 16 bar - sewers, outfall pipes, industrial pipesPE 100 - high demands piping applicationsThe Minimum Required Strength - MRS - according ISO 4427 for the different materials are:Designation of materialMRS at 50 years and 20oCMpa (bar)PE 10010 (100)PE 808 (80)PE 636.3 (63)PE 404 (40)PE 323.2 (32)


Why does your well water come to stop and surge back on after a couple seconds when attempting to fill my tub?

There is insufficient head in your piping. is your tub half full when it surged? if it is, that means ur tub pressure before surging has the same pressure as ur piping. simply put it, ur piping is working it way up to ur tub in a vertical piping which is too high. do u have a pump? if it is natural flow, that means your well does not have sufficent volume. when insufficient volume, u do not have the weight to hold the pressure in the piping. fluid flow will always try to find its equilibrium. when it reaches, it will stop. its starts to surge back after a few seconds due to the inertia of the water. when equilibrium, the water will surge back to the well. if there is no pump, install one. that will solve all problems. if u have a pump, ur pump in undersized to do the work required which is in this case to push water out from the piping in to ur tub. u will need a larger capacity pump rating. i hope


Does a high-pressure system have a low-pressure or high-pressure center?

A high pressure systems has a high pressure center.


What is the best piping type for outside plumbing?

Any kind of non plastic piping will do (namely copper or galvanised for water and uPVC for Waste). Unless of course this cannot be done due to high theft of metallic piping.


What would cause a sump pump to run continuously and only recirculate sewage in crock?

=2- Pumping against too high a head (static pressure) cause by excessive piping or a partial stoppage or undersized piping or to many restrictions such as short radius ells or a bad check valve==3- float not properly set=


Where are the ports front and rear on a 1997 gm suburban so you can refill the freon what freon is used?

Virtually all vehicles since 1994 use refrigerant r-134a. On a 97 Suburban, the suction (low pressure) and discharge (high pressure) ports are located on top of the compressor. Refrigerant is added to the low pressure side. It is attached to the larger refrigerant piping and hose which runs to the accumulator-drier at the firewall. The smaller high pressure pipe attaches to the condenser located in front of the radiator. Do NOT attach a refrigerant can to the high pressure line.