Q: What processes must take before using micrometer?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Physics

Why is it necessary to calibrate the ocular micrometer with each objective?

The ocular micrometer is inside the ocular lens, it will not change size when the objectives are changed. Therefore, each objective lens must be calibrated separately. Ocular micrometers have no units on them - they are like a ruler with marks but no numbers. In order to use one to measure something under a microscope, you must assign numbers to the marks. This is done by looking through your OCULAR micrometer at a STAGE micrometer mounted on a slide. The stage micrometer is just a ruler with fixed known distances, so you can use it to tell how far apart marks are on the ocular micrometer. This has to be done because the marks on the ocular micrometer are different distances apart depending on the magnification used on the microscope. It must be calibrated for each objective.


What skills and processes must be used to accurately collect analyze and report data?

there are no skills


What are the errors in micrometer screw gauge?

This micrometer has zero error.The zero marking on the thimble is below the datum line. So this micrometerhas a positive zero error.In this case we will take the reading on the thimble.Thimble reading = 0.03 mmSo the micrometer has a zero error of +0.03 mm.Whatever reading we take on this micrometer we would have to subtract +0.03 mmThe zero marking on the thimble is above the datum line. So this micrometerhas a negative zero error.In this case we will have to count the number of divisions on the thimble between the zero marking and the datum line.No. of divisions = 3Measurement of each division = 0.01mmSo the micrometer has a zero error of -0.03 mm.Whatever reading we take on this micrometer we would have to subtract -0.03 mm


What must you do first before determining gravitational PE?

you must determine hight


What must you do before making a prediction?

make a hypothesis.

Related questions

What is the expected Error using micrometer?

the spindle must be tighten to avoid slightly changes on the reading


What two processes must occur before seeds can form a cycle?

pollenseed


What two processes must occur before seeds can form a new cycle?

pollenseed


What must they do before using it?

calibrate it .


What two processes must take place before an unconformity can form in geology?

Erosion and deposition


What are two processes a rock must undergo before it can become in an igneous rock?

melting andsolidification


What are three processes that a metamorphic must experience before it can become a sedimentary rock?

ErosionDepositionBurial and Cementing


What are three processes that a metamorphic rock must experience before it can become a sedimentary rock?

ErosionDepositionBurial and Cementing


What are three processes that a metamorphic rock must experience before it can become sedimentary rock?

ErosionDepositionBurial and Cementing


What are three processes that metamorphic rock must experience before it can become a sedimentary rock?

ErosionDepositionBurial and Cementing


Why is it necessary to calibrate to ocular micrometer with each objective?

The ocular micrometer is inside the ocular lens, it will not change size when the objectives are changed. Therefore, each objective lens must be calibrated separately. Ocular micrometers have no units on them - they are like a ruler with marks but no numbers. In order to use one to measure something under a microscope, you must assign numbers to the marks. This is done by looking through your OCULAR micrometer at a STAGE micrometer mounted on a slide. The stage micrometer is just a ruler with fixed known distances, so you can use it to tell how far apart marks are on the ocular micrometer. This has to be done because the marks on the ocular micrometer are different distances apart depending on the magnification used on the microscope. It must be calibrated for each objective.


Why is it necessary to calibrate the ocular micrometer with each objective?

The ocular micrometer is inside the ocular lens, it will not change size when the objectives are changed. Therefore, each objective lens must be calibrated separately. Ocular micrometers have no units on them - they are like a ruler with marks but no numbers. In order to use one to measure something under a microscope, you must assign numbers to the marks. This is done by looking through your OCULAR micrometer at a STAGE micrometer mounted on a slide. The stage micrometer is just a ruler with fixed known distances, so you can use it to tell how far apart marks are on the ocular micrometer. This has to be done because the marks on the ocular micrometer are different distances apart depending on the magnification used on the microscope. It must be calibrated for each objective.