Q: What should the suction pressure be on a 85 degree day on a 410A split unit?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What should the suction pressure be on a 85 degree day on a R22 split unit?

60psi


How do you use the temperature pressure table when measuring suction pressure on your split system air conditioner?

i think you subtract the evaporator temp from the outside temp?


How cold should the air be blowing out of the vents when the central AC unit is running properly?

There should be at least a 12 degree split between the incomming air and the air comming out of the vents.


How much pressure should be applied to common water in order to split it to its element H2 and O2?

Mechanical pressure will not split water into its component elements.


Should all swimming pools be built with two drains for safety?

The main drain should be split to two drain basins at least three ft. apart. This is done to prevent suction entrapment.


Should the suction line be cold?

On split system installations, the suction line should be pitched towards the compressor at least Suction line should be insulated for 2 reasons: 1) so it does not drip condensation everywhere it passes through the homes interior space. ie attic, inside walls etc. 2) cool suction gas is what cools the compressor motor during operation, insulating the pipe carrying it helps prevent that gas from picking up heat from the surrounding air ensuring it remains an effective coolant for the motor. The original reply was also correct, an effort to pitch the suction line towards the compressor should be madr wherever possible to aid in oil return.


What should the temperature of air from the AC vents be?

normally 15to 20 degree split between return air and discharge..


What are the procedure for pumping down a Split ac system?

Connect your refrigerant gauges, jump out the low pressure safety control, start the unit and after it has settled out, front seat the liquid line service valve. Monitor the suction and discharge pressures when they both reach 10``wc. Shut the machine off and quickly front seat the suction service valve.


What is an AC compressor?

Commonly referred to as the heart of the system, the compressor is a belt driven pump that is fastened to the engine. It is responsible for compressing and transferring refrigerant gas. The a/c system is split into two sides, a high pressure side and a low pressure side; defined as discharge and suction. Since the compressor is basically a pump, it must have a intake side and a discharge side. The intake, or suction side, draws in refrigerant gas from the outlet of the evaporator. In some cases it does this via the accumulator.


Why individuals should not be dragged in relation to pressure sores?

First of all, people should always be lifted, never dragged. If you were to drag soemone with pressure sores, they would split open even further and become infected.


Does a gymnast exert more pressure on the floor when she does a handstand or when she does a split?

The gymnast exerts more pressure by doing the split because she has a bigger surface.


How do you remove a clog without losing all freon from the thin copper tube on the low pressure side of a split AC that is frozen for 10 inches then a couple of fittings and it is warm from there on?

There should be a pump down valve at the condenser. One for the suction and one for the liquid side. Simply front seat the valve on the liquid line and wait for the unit to pump down, then front seat the suction side and cut the pipe and replace. You may want to install a liquid line dryer before you evacuate the system and recharge the unit.