You should check that you are not running too many appliances on the circuit that is protected by the circuit breaker.

If you are absolutely sure that the circuit is not being overloaded, you should replace the breaker with a new identical breaker. Breakers get hot when they supply power at near peak amperage over a long period of time and begin to break down internally.

<><><>

As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.

Before you do any work yourself,

on electrical circuits, equipment or appliances,

always use a test meter to ensure the circuit is, in fact, de-energized.

IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB

SAFELY AND COMPETENTLY

REFER THIS WORK TO QUALIFIED PROFESSIONALS.

User Avatar

Wiki User

13y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What should you do if your circuit breaker is hot?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

An open circuit results when a hot wire touches ground?

A short circuit is the term for hot touching ground. This can cause a breaker to trip which will then open the circuit.


Circuit breaker trip cause smoke will homeowner insurance pay for it?

A circuit breaker does not "cause" smoke. A circuit breaker "breaks" a circuit when there is too much current, creating a hazardous condition for the wires that are connected to the circuit breaker. The circuit breaker PROTECTS you from electrical fire. Find the source of the smoke; what burned? If a circuit breaker tripped during the incident, it is usually caused by melting/burning wire insulation, either inside or outside of an appliance. If the insulation inside the walls of your house has burned/melted, it could be that the circuit breaker was too large for the wire or that the circuit breaker failed to shut off at the appropriate current load. If the circuit breaker failed, your insurance should help you. If an appliance overloaded the circuit, your insurance should help you. If someone connected an oversized circuit breaker, causing the wire to overheat, your insurance company may refuse to help you.


Can a circuit breaker be tripped by using 20 amp sockets instead of 15 amp sockets?

A circuit breaker protects the wires that the devices are connected to. If the devices that are connected to the circuit are 20 amps the wire size should be #12 wire fed from a 20 amp breaker. This breaker should not trip unless the circuit is overloaded or a fault occurs on the circuit. If the devices that are connected to the circuit are15 amps the wire size should be #14 wire fed from a15 amp breaker. This breaker should not trip unless the circuit is overloaded or a fault occurs on the circuit. Putting 20 amp sockets on this 15 amp circuit will work but the circuit is limited to the amount of load that can be plugged in. You will not get the full capacity of the 20 socket because the breaker will trip at 15 amps.


What is a Circuit breaker and explain type circuit breakers?

A circuit breaker is a switching device which can make,brake and carrying (or trip the circuit) that specified over currents for a small interval of time . There is a different types of Circuit Breaker's are there 1.According to their arc quenching media these are divided into 4 types a) Oil circuit breaker b) Air blast circuit breaker c) SF6 circuit breaker d) vacuum circuit breaker 2. According to their services the circuit breaker can be divided as a) Outdoor Circuit Breaker b) Indoor Breaker 3. According to the operating mechanism of circuit breaker they can be divided as a) Spring operated Circuit Breaker b) Pneumatic Circuit Breaker c) Hydrolic Circuit Breaker 4. According to the voltage level of installation these are divided into 3 types a) High Voltage Circuit Breaker b) Medium Voltage Circuit Breaker c) Low Voltage Circuit Breaker.


What size amp ciruit breaker should used for a 220volt hot tub?

It should be on a dedicated circuit and should match the rating on the tub. There will be a plate somewhere on the tub with the rated amperage.

Related questions

Where is the circuit breaker for a hot water heater?

The best way to determine which circuit breaker is for the water heater is with a voltage meter, It is suppose to be only one circuit breaker, but in a faulty application it could be two breakers


How are Branch circuit protected?

Branch circuits are protected by the circuit breaker found in the electrical panel. Each circuit should have its one breaker. The breaker should be rated to protect the insulation of the wire, so you can determine the breaker size based on the circuit conductor size Example #14-2 should be protected by a 15 amp breaker


What should you do to the surge strip if the circuit breaker fails to reset?

You should replace the surge strip if the circuit breaker fails to reset.


An open circuit results when a hot wire touches ground?

A short circuit is the term for hot touching ground. This can cause a breaker to trip which will then open the circuit.


Do you shut the water valve first or the hot water circuit breaker when going away for an extended vacation?

the hot water circuit beaker


What do I do if there is no circuit breaker for outdoor light?

If you have a light that is not being powered through a circuit breaker or fuse, you should call a qualified electrician to remove this circuit from the panel's bus and install a circuit breaker for it. Without an overcurrent protective device (circuit breaker or fuse) you have a potential fire hazard.


Must wires be connected to breaker box?

It should be connected to circuit breaker. Circuit breaker will automatically discontinue the flow of electricity if it detects faulty condition.


What size circuit breaker should be used for dishwasher and disposal?

A 15 amp dedicated circuit breaker should be used for the dishwasher. The disposal can be wired to the general kitchen 15 amp circuit.


A parallel circuit breaker should be connected in a parallel to the circuit it's protecting?

For a circuit breaker to protect anything, it must be wired in series with whatever it is protecting.


Circuit breaker trip cause smoke will homeowner insurance pay for it?

A circuit breaker does not "cause" smoke. A circuit breaker "breaks" a circuit when there is too much current, creating a hazardous condition for the wires that are connected to the circuit breaker. The circuit breaker PROTECTS you from electrical fire. Find the source of the smoke; what burned? If a circuit breaker tripped during the incident, it is usually caused by melting/burning wire insulation, either inside or outside of an appliance. If the insulation inside the walls of your house has burned/melted, it could be that the circuit breaker was too large for the wire or that the circuit breaker failed to shut off at the appropriate current load. If the circuit breaker failed, your insurance should help you. If an appliance overloaded the circuit, your insurance should help you. If someone connected an oversized circuit breaker, causing the wire to overheat, your insurance company may refuse to help you.


What are the breaker ampere trip ratings?

The ampere frame rating for a circuit breaker designates how the circuit breaker should be configured. It also states the trip unit of the amp.


Can a circuit breaker be tripped by using 20 amp sockets instead of 15 amp sockets?

A circuit breaker protects the wires that the devices are connected to. If the devices that are connected to the circuit are 20 amps the wire size should be #12 wire fed from a 20 amp breaker. This breaker should not trip unless the circuit is overloaded or a fault occurs on the circuit. If the devices that are connected to the circuit are15 amps the wire size should be #14 wire fed from a15 amp breaker. This breaker should not trip unless the circuit is overloaded or a fault occurs on the circuit. Putting 20 amp sockets on this 15 amp circuit will work but the circuit is limited to the amount of load that can be plugged in. You will not get the full capacity of the 20 socket because the breaker will trip at 15 amps.