answersLogoWhite

0

Electric dryer, electric range and central air conditioner. Some people also have a 220v outlet in their garage or workshop to run equipment like a welder or air compressor.

User Avatar

Wiki User

13y ago

What else can I help you with?

Related Questions

How much can a 15W circuit breaker handle?

Answer for the US: Breakers are rated in amps, not watts. However, a 15A breaker can handle 15 amps, or about 1800 watts (using 120V), or 3600 watts (using 240V). However, this is only rated for noncontinuous loads (those not lasting for more than three hours). For continuous loads (loads lasting three hours or more), one must derate the circuit breaker by 80%. So for continuous loads, that same breaker should only have 1440 watts (using 120V), or 2880 watts (using 240V) on it.


What is the protocol for determining the winner in a full house tie breaker in a poker game?

In a full house tie breaker in poker, the winner is determined by the rank of the three matching cards in the full house. The player with the higher ranking set of three cards wins the hand. If both players have the same ranking set of three cards, then the two matching cards in the full house are compared to determine the winner.


How do you install a 110v receptacle from a 3 phase breaker box if there are no neutrals in the breaker box?

If there is no neutral available you cannot, unless you use an autotransformer and derive a neutral. A panel with no neutral is called a power panel and is used to supply 240 single and three phase loads.


Is there continuity between a three pole circuit breaker terminals?

No, the three individual poles of a three phase circuit breaker are not electrically connected to each other. If they were, a fault would develop internal to the breaker.


How many wires are used for a 460 volt circuit breaker?

If the load is single phase and the load requires 460 volts to operate, then two conductors will be needed and they will connect to a two pole breaker. If the load is three phase and the load requires 460 volts to operate, then three conductors will be needed and they will connected to a three pole breaker. The sizing of the wires will depend upon the current that is drawn by the loads.


What is 4 pole circuit breaker?

I have never seen a four pole circuit breaker. Breakers are single, two and three pole. Single pole for 120 volts, two pole for 240 volts and three pole for three phase loads. In North America all neutrals are SN (solid neutrals) and are not switched. In certain applications using a three phase Y-connected load, where complete isolation of the load from the supply is required, the neutral line connects to one pole of a 4 pole circuit breaker.


What are the powers of 3?

The three main powers are the House of Representatives, the Senate, and their Committees. We all know what the first two do, but the Committees help out by being a tie-breaker.


How can you connect single phase generator in three phase supply system in house lighting system?

First house lighting systems are single phase not three phase. To connect a generator to the house lighting system for emergency power, it would take an electrician to do the job properly. The biggest concern would be to isolate the rest of the service from the main distribution supply service and then isolate the rest of the distribution panel loads from the lighting loads.


What are the 3 powers of congress?

The three main powers are the House of Representatives, the Senate, and their Committees. We all know what the first two do, but the Committees help out by being a tie-breaker.


How do you get a double bed in harvest moon magical melody wii?

You must upgrade your First house to level three. Then the Double Bed will become available in Woody's store. To get the option to upgrade your house to level three you must befriend Woody, Kurt, and Joe.


What are the three ancient civilizations?

there are loads and loads! The three most people know are of course Egypt, Greece and Rome


How can I connect a single-phase - 2 hot wires plus ground- 220V load to a 3-pole 220V breaker?

Common usage of a three pole breaker is for use on a three phase distribution panel. Single phase distribution panels only use two pole breakers for a 240 volt load.Remember that the breaker must protect the conductors that connect to the load. If you want to try and use a three pole breaker in a single phase panel just because you have the breaker, this is not a good idea even if it will fit.Purchase the proper single phase two pole breaker to match the wire size and the amperage of the connected 240 volt load. Keep in mind that connected 240 volt motor loads have to be sized to 250% of the motor's full load amperage.By doing what you want to do and a fault occurs from this type of installation your insurance company might not cover the damage that it would cause.If the distribution panel is three phase then just connect the two load wires to any two of the three poles on the breaker.