Q: What will happen if a 88kv bushing is installed in a 132kv rated transformer?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What will happen if a new branded 132KV transformer is charged at the IR value of 150Megaohm between HT winding and Earth remaining IR values being found infinity?

Sir I am Imran khan in nepal my problem is 6000KVA Step down Transformer is not charging. Transformer Pri- 33000V /105A Sec- 6900V / 502Atransformer all test (open & short circuit ) good . but problem is HT(IR)= value this time IR value 50M ohmBefore 3days HT(IR) = value is 7000M ohm suddenly start Transformer result is Transformer not charging & HT(IR) value is down 50M ohm.


What is an acceptable value of 132kv Isolator contact resistance test?

132kv MOCB acceptable value of somthing 150 micro ohms.


How many disk insulator used for 132kv?

9 insulators


What is a 380 132 substations?

it means..it is stepping up the power of 132KV to 380KV on the transmission lines.


Safety distance from 132kv power line?

The safety distance from a 132 kv powerline is 1.4 metres


What does a primary substation do?

Primary substation - when the transformer is HV/MV or MV/MV. e.g. substation designed for 132kV/33kV or 230kV/22kV or 33kV/11kV etc stepped down for MV distribution (mainly for utilities and heacy industries) Secondary substation - when the transformer is HV/LV or MV/LV. e.g. substation designed for 11kV/400V or 6.6kV/400V etc stepped down for LV distribution (mainly for residential, commercial) sometime referred to as a kiosk substation.


What is Indian railway transmission line voltage?

220v, 415v, 6.6 kv, 11kv,33kv,132kv,400kv


Design of earthing calculation 132 kv switch-yard?

Refer IEEE 80- 2003 For Design of grounding of 132kV substation.


What is the voltage of high tension electrical transmissions towers?

Usually HV is 33KV and 66KV, EHV is 132KV, 220KV and 400KV and UHV is 800KV and 1200KV


How much voltage for 132kv UG cable high voltage testing?

it depends on the specification,,,,,,in saudi arabia as per sec standards 152kv voltage should be applied for a period of one hour.


What is 132kv tower height?

the general height is 25-27mts,the first conductor is placed 17mts above the ground and rest of conductors placing 1st-2nd is 3.1mts and 2nd-3rd is 2.6mts


Explain the transmission and distribution of electricity from the generation station to the consumer?

transmission and distribution of electricity are the way of regulate voltage to the minimum rate in which can be benefit to the consumers. From generating station , voltage generated is up 16/25kv which step up upto 330kv this generating voltage now step down in the transmission station through the step down transformer which is 132kv this voltage now transmitting to distribution station where voltage now step down to 33kv, this 33kv now stepdown to 415v for three line and 240/220v for a line for the uses of consumers.