DC shunt motor can be reversed by changing the polarity of either the armature coil or the field coil.
the direction changes with change in polarity of field supply.
To reverse the direction of rotation of DC Shunt motor, armature connections should be done reverse or field connections can be done reverse.
Swap over the two connections to the armature, or the field, but not both.
the direction of the rotation of dc shunt generator could be changed only by changing the direction of rotation of the prime mover
It fails to build up because self excited DC motor's armature have only one direction of rotation. So that if the poles of the armature are reversed, then this causes the reduction in the residual magnetism and eventually, it will stop.
Answer:If the shunt winding is open the motor won't start, but if the shunt open while the motor is running, the motor will keep on running as if nothing went wrong, except if the wire of the winding get maniacally between the stator and the fields the motor can be damaged beyond repair. But normally the shunt windings is done with very thick conductors, so the chance that the shunt will go open is zero.
Dc shunt motor is a constant flux and constant speed motor . So that it is used in centrifugal pumps ,machine tools ,blowers and fans etc.
Yes. The field is provided by the shunt windings, which are connected in parallel with the supply. You may be confusing a motor with a generator, as you cannot start a shunt generatorwithout residual magnetism.
DC shunt motor can be reversed by changing the polarity of either the armature coil or the field coil.
the direction of the rotation of dc shunt generator could be changed only by changing the direction of rotation of the prime mover
load test on dc shunt generator is a test to plot the internal and external characteristics of the generator.
It fails to build up because self excited DC motor's armature have only one direction of rotation. So that if the poles of the armature are reversed, then this causes the reduction in the residual magnetism and eventually, it will stop.
Reverse the armature connections or the field connections, but not both.
yes.because the direction of motor is same in both half cycles
A shunt DC motor connects the armature and field windings in parallel or shunt with a common D.C. power source. This type of motor has good speed regulation even as the load varies, but does not have the starting torque of a series DC motor
A DC shunt motor is a motor using DC supply with the the inductor connected parallel to the armature.
Dc shunt motor is constant speed motor.Its speed is constant with armature current.This shunt motor is used in paper mills and drilling machines
Answer:If the shunt winding is open the motor won't start, but if the shunt open while the motor is running, the motor will keep on running as if nothing went wrong, except if the wire of the winding get maniacally between the stator and the fields the motor can be damaged beyond repair. But normally the shunt windings is done with very thick conductors, so the chance that the shunt will go open is zero.