answersLogoWhite

0

It could be anything, it depends on the design of the motor and whether it is a high-power or a low-power motor.

What else can I help you with?

Related Questions

Why use capictor in motor?

To create rotating magnetic field inside motor stator and it is done by capacitor. current drawn by motor running winding is lagging in nature when capacitor is connected in series with starting winding then the phase angle of running winding current and starting winding currents changes which creates a rotating magnetic field and motor is able to run.


What would the power loss be if the series field winding of dc motor connected directly across the 240 V dc supply?

Detailed Solution. For a constant back emf, flux is inversely proportional to the speed of the motor. If field winding is disconnected accidentally, the speed would dangerously increase in order to maintain the back emf of the motor


What field setting for a dc shunt motor wired in series on high voltage?

A shunt dc motor has quite different characteristics from a series motor. Wired in series, the same current passes through the armature and the field winding and it is most unlikely that a shunt motor would have a field winding that is suitable for this. Therefore a shunt motor cannot be wired as a series motor in general because its field winding is designed for only a small current.


How demagnetize an electric motor?

A transformer winding only produces a magnetic field when current flows through it. Switch the current off, and the magnetic field disappears. You do not need to 'demagnetise' a transformer winding.


What is separately excited DC motor?

The main difference between the Separately excited motor and the shunt motor is the field cct where as in the second it has its own voltage supply.AnswerI think you mean 'generator', not 'motor'. A 'self-excited' motor is one in which the output supplies the field current, as well as the load current. A 'separately-excited' motor is one in which the field current is provided from an external source.


What happens if field winding of a running dc shunt motor suddenly breaks open?

when the field winding of a running dc shunt motor suddenly breaks open the motor fails to run because in the motor the stationary winding is armature and rotatory is field winding


When the dc motor is connected across an AC supply then?

It depends on the construction of the motor. If the field winding is connected in series with the armaturewinding, the motor is like a universal motor and will probably operate normally. If the field winding is connected in parallel with the armature, the motor will not run, but will draw current, make noise and get hot.


What is the difference between a field winding and an armature winding in any machine?

In electrical machines such as motors and generators, the field winding is responsible for producing a magnetic field within the machine. This magnetic field interacts with the armature winding, which carries the electric current and generates mechanical power. The field winding typically has fewer turns of thicker wire compared to the armature winding, which has more turns of thinner wire to handle higher currents.


What are field windings and armature windings in a dc motor and generator?

generators have two types of winding , * at armature also called armature winding( winding around shaft , we can say), which is the moving part. note that armature also consists of magnets along with windings. hence produces field arount it. * and at stator also called field winding, because when armature rotates its flux(field) is cutted by the stator windings and produces mutually induced e.m.f in it( in stator windings off course) causing current to flow. this current also produces some electric field around it which is in return cutted by the armature windings hince a little amount of e.m.f ( also called back e.m.f) produced in armature due to stator winding current. know this current in armature (due to back e.m.f produced by stator winding) produces additional field , hence causing more current in stator winding. this is the reason that why stator windings are called field winding( as they cause electric field of armature stronger and cause more current in output). note that out put is taken from the stator windings in generators.


If a current of 3 A dc flows in the series field winding of your motor what wouldthe resultant voltage drop be?

The voltage drop across the series field winding of a motor can be calculated using Ohm's Law (V = I × R), where V is the voltage drop, I is the current, and R is the resistance of the winding. If the resistance of the series field winding is known, you can multiply it by the current of 3 A to find the resultant voltage drop. Without the specific resistance value, the exact voltage drop cannot be determined.


If the series field winding of your motor was connected directly across the 120 V dc supply a. What current would flow?

If the series field winding of a motor is connected directly across a 120 V DC supply, the current that flows through the winding would depend on the resistance of the winding itself, as per Ohm's Law (I = V/R). If the resistance of the winding is known, you can calculate the current by dividing the voltage (120 V) by the resistance (R). Without knowing the specific resistance value, the exact current cannot be determined.


Can a shunt field winding be used as a series field winding in dc series motor?

aster