answersLogoWhite

0

What else can I help you with?

Related Questions

Why does the mercury not fall or rise in a clinical thermometer when taken out of the mouth?

Mercury does not fall or rise in a clinical thermometer when taken out from the mouth because of the KINK present in it.


What precautions should be taken when using mercury base thermometer?

don't break it. If you do open the windows.


What is the function of constriction in clinical thermometer?

In case of ordinary thermometer if the thermometer is taken out the body whose temperature has been seen, the Mercury would fall down as the bulb gets cooled. But in case of clinical thermometer even after the thermometer has been taken out of the mouth of the patient the level of mercury would be held at the same level though the bulb falls to the room temperature. So doctor could see the temperature liesurely. To bring back the mercury to lowest level we have to give jerks to the thermometer by shaking it.


How does a mercury thermometer measures temperature?

A mercury thermometer measures temperature based on the expansion or contraction of the liquid mercury inside the narrow tube. As temperature rises, the mercury expands and travels up the tube, indicating a higher temperature, and vice versa. The temperature reading is taken at the point where the mercury level stabilizes.


Why is kink provided in a clinical thermometer?

The kink in a clinical thermometer prevents the column of mercury from falling back down when the thermometer is removed from the patient's body, allowing for an accurate temperature reading to be taken and read.


Why is there a constriction in a clinical thermometer?

The constriction prevents the mercury from returning back to the bulb when the thermometer is removed from a particular body.


Why the reading of thermometer is taken when the mercury stop expanding?

The mercury will expand and rise up the thermometer tube until it reaches the temperature of the air around it. When it stops expanding, it is the same temperature as the air, and therefore gives an accurate reading.


Why is a clinical thermometer usually shaken after use?

Well, a clinical thermometer is shook after use so that the mercury comes back to its initial point i.e. where it had been before the temperature was taken.


Why does the mercury fall or rise in a clinical thermometer when it is taken out of the mouth?

A clinical thermometer measures the max temp of the human body due to the expansion of the mercury in the bulb, which flows past a kink in the column and rises in the graduated stem, to read the highest body-temp. Once it is removed from the body, the mercury stays at that level, and does not fall because it cannot flow back into the bulb -- the kink prevents the back flow. It has to be shaken vigorously, as you know, for us to get the mercury back; then it is ready to take the temp again.. Also, the temp cannot rise further on its own from the max reading because the mercury does not expand the moment the thermometer is taken out of the body. Incidentally, temp can be measured under the armpits and in the rectum also.


Why care must be taken when disposing of a mercury-in-glass thermometer?

Well i'm not that old but i know a few:1)The thermometer will be of two types; a) Clinical Thermometer b) Laboratory Thermometer;a) The Clinical Thermometer: used to measure the temperature of the human body, at home, clinics and hospitals.b) The Laboratory Thermometer: used to measure the temperature in school and other laboratories for scientific research.Precautions:Wash the thermometer before and after use with an antiseptic solution, and handle it with care.See that the mercury levels are below the kink and don't hold the thermometer near its bulb.While noting down the reading in the thermometer, place the mercury level along the eye sight.Do not place the Clinical thermometer in a hot flame or in the hot sun.Note:The Clinical Thermometer should go above 108*F (42*C) and below 94*F (35*C) otherwise it might blow off the top and leak. Therefore, a Clinical Thermometer is used to measure the body temperature.


Why is there a need for us to shake the clinical thermometer prior to each use?

If the clinical thermometer is a mercury based thermometer, it needs to be shaken down prior to each use. This is because there is a pinch point between the mercury reservoir bulb and the capillary tube, to ensure that the mercury does not shrink back into the bulb after the temperature has been taken. The mercury has therefore to be shaken back into the bulb before another measurement can be made. One should note that in many countries use of mercury based clinical thermometers is now discouraged (because mercury is toxic) and electronic thermometers are used in stead - these do not need shaking.


What precautions should be taken while using a laboratory thermometer?

Precautions need to be taken while using clinical thermometer are: _ Wash the thermometer after and before using it._* _ Make sure the temperature of the thermometer is below 35 C before taking the temperature._* _ Keep the thermometer straight in the order to see the Mercury level precisely._*