Want this question answered?
The experimental molar heat of combustion is the heat released by the total combustion of a substance, determined in a calorimeter.
Heat of combustion is a chemical property of matter.
You think probable to molar heat, expressed in J/mol.
Petrol has a higher value of the heat of combustion.
Combustion requires Heat, Fuel and Oxygen
preheater is used to heat the air at Inlet of the furnace of Boiler By using Heat contents of Exhaust gases. This will minimize the fuel Consumption.
It is the small space between two plates having water and at the other side of the plate hot gases are available to transfer heat to the boiler water. In fire tube boiler space between end plate and combustion chamber's end plate is called water leg.
heat, smoke, toxic gases
Probably about 25 percent of the heat of combustion goes up the stack
Basically . economiser is located in between exit of boiler and entry of air preheater. when the flue gases are coming out from boiler they take away a lot of heat. economiser utilize this heat from flue gases. and these heat is used to heat the feed water which is going to feed the bolier. hence by using economiser the coal consumption required to heat the feed water is reduced hence cost reduced.
An economizer is used to heat boiler feedwater up closer to the temperature of the boiler water, using heat from the boiler exhaust gases, heat that would otherwise be wasted. The main reason is to improve the efficiency of the boiler. For every 44 degree F drop in exhaust gas temp. there is an 11 F rise in feedwater temperature and a 1% gain in boiler efficiency.
Probably about 25 percent of the heat of combustion goes up the stack
because of heat transfer rate is better
In a power station boiler, or steam raising unit to be more correct, heat flows from the hot flue gases produced by combustion of coal or oil or gas, or from the hot water outlet of a nuclear reactor, into the feedwater pumped into the boiler secondary side, and produces steam.
Economizer is a device in which the waste heat of the fuel gases is utilized for heating the feed water.
Basically . economiser is located in between exit of boiler and entry of air preheater. when the flue gases are coming out from boiler they take away a lot of heat. economiser utilize this heat from flue gases. and these heat is used to heat the feed water which is going to feed the bolier. hence by using economiser the coal consumption required to heat the feed water is reduced hence cost reduced.
Heat exchangers are built for efficient heat transfer. I would recommend buying them for your home. Older heating systems have a constant pilot light and creates a flow of combustion gases. while newer, high efficiency heating systems have sealed combustion and condenses gases into the heat exchanger for more efficiency.