Why does refrigerant pressure decrease in a refrigerant cylinder while charging with vapor?

When vapor refrigerant is pulled out of a cylinder the vapor is reduced and the liquid boils to replace the vapor that has left the cylinder.


When charging a system with vapor refrigerant from a refrigerant cylinder the cylinder will become?

Lighter, as the refrigerant is boiled off, and colder, as it has absorbed heat, and has a lesser pressure to reflect the current temperature / pressure relationship for the type of refrigerant


When charging a system with vapor refrigerant from a cylinder the cylinder will become?

Lighter, as the refrigerant is boiled off, and colder, as it has absorbed heat, and has a lesser pressure to reflect the current temperature / pressure relationship for the type of refrigerant


When filling a charging cylinder the refrigerant that is vented off the top of the cylinder?

Must be recovered


When filling a charging cylinder the refrigerant that is vented off the top of the cylinder .?

Must be recovered


When filling a charging cylinder refrigerant that is vented off the top of the cylinder?

Must be recovered


How is the refrigerant cylinder pressure kept above the system pressure when charging with vapor from a cylinder?

The refrigerant cylinder is heated in a tub of water to no more than 90 degrees F. Electric heating blankets manufactured for this purpose may also be used.


Why is the gauge line secured when the refrigerant cylinder is on the scale while transferring refrigerant?

The gauge line is secured when the refrigerant cylinder is on the scale while transferring refrigerant to prevent the refrigerant from leaking out. If the refrigerant were to leak out, it would cause the scale to become inaccurate, and it would also be a safety hazard.


What is a reason to obtain an accurate pressure reading of refrigerant inside a recovery cylinder?

Damaged refrigerant


What would the result be if a recovery cylinder were filled with liquid refrigerant and allowed to warm up?

The result of filling a recovery cylinder with iquid refrigerant and allowing it to warm up is that the heat of the container would warm the refrigerant inside of it. The refrigerant would, as a result expand.


What would the result be if a recovery cylinder were filled with liquid and allowed to warm up?

The result of filling a recovery cylinder with iquid refrigerant and allowing it to warm up is that the heat of the container would warm the refrigerant inside of it. The refrigerant would, as a result expand.


How is the refrigerant cylinder pressure kept above the system pressure when a system is being charged with the vapor from a cylinder?

Add refrigerant vapor on the low side of the system ,the compressor raises the pressure of the refrigerant on the high side of the system and lowers the pressure on the low side