Want this question answered?
If a motor is connected in a star configuration it will operate at a slower speed. This is the working process that a star delta starter operates on. At first through the starter the motor starts in the star connection. When the motor gets up to its highest speed in that connection it times a timer out , the star starter drops out and the delta starter pulls in and then connects the motor in the delta connection. This allows more voltage to be applied to the motor and it then speeds up to its nameplate rated RPM.
If the motor terminal has six terminals in the terminal box, then it can be connected either in delta or star. If there are only 3 terminal wires then the motor can not be connected in star.(it means that the motor is designed to be connected in delta only)
A star configuration of the windings in a 3-phase transformer or motor is where one end of each winding is connected to form a star or 'Y' pattern and the other ends are each connected to one of the three separate lines of the incoming 3-phase electrical service.A delta configuration is when each phase winding of a three phase transformer or motor is connected to its two adjacent phase windings to form an arrangement that looks like the Greek letter delta - or triangle - and then each point of the triangle is connected to to one of the three separate lines of the incoming 3-phase electrical service.To be able to wire a 3-phase transformer or motor either in star or delta, all 6 ends of the three sets of coils, called "windings", have to be exposed with suitable connection terminals.The windings are often labelled A1, A2, A3 and B1, B2, B3, where "1", "2" and "3" denote the separate phase windings and "A" and "B" denote the beginning and end of each winding.Another way of describing it is to say that the separate windings can be labelled:Winding 1: A1 B1. Winding 2: A2 B2, Winding 3: A3 B3.In star configuration either all the A's or all the B's are connected together and the 3-phase supply (consisting of three separate "phase lines" labelled L1, L2, L3) is connected to the remaining three connectors. For example, if you connect B1 to B2 and B2 to B3 to form the center of the "star" then you must connect supply L1 to A1; supply L2 to A2 and supply L3 to A3.In delta configuration, connect B1 to A2, B2 to A3, B3 to A1. (If you draw that out as a schematic diagram, it will be a triangle.) Then connect supply L1 to A1; supply L2 to A2 and supply L3 to A3. (Exactly the same as the supply lines were connected before, for the star configuration.)For more information see the answers to the Related Questions shown below.
Common base connection.
two contecter <<>> There are three contactors used in a Star Delta configuration.
Generators were supplied and connected to power lines.
If a motor is connected in a star configuration it will operate at a slower speed. This is the working process that a star delta starter operates on. At first through the starter the motor starts in the star connection. When the motor gets up to its highest speed in that connection it times a timer out , the star starter drops out and the delta starter pulls in and then connects the motor in the delta connection. This allows more voltage to be applied to the motor and it then speeds up to its nameplate rated RPM.
400 volts 3 phase is the standard voltage in Europe, and wind generators originated in Europe. 3 phase induction motors are readily available and become induction generators when driven faster than there syncronous speed mechanicaly by an external force, like the wind in the case of wind generators. Motors are typically delta connected and have 400 volt windings. In the case of generators there is an efficiency gain by configuring the 400 volt windings in a star configuration because the higher voltage will yield a lower current allowing a smaller diameter conductor. Square root of three times 400 volts equals 690 volts. Viola!
they where used on hoth to destroy the generators
A: only if both are perfectly matched in their output
MPLS is pretty complex, and the configuration will depend entirely on the device to which it's connected. Presumably, that's your ISP's router on the other end. They should tell you what configuration you need to use.
Honeywell generators are not energy star approved. This is because a generator is usually a source of backup power, or sole power if in a very rural area. They use a lot of energy and therefore are not energy star approved.
The Sun is a star.
If the motor terminal has six terminals in the terminal box, then it can be connected either in delta or star. If there are only 3 terminal wires then the motor can not be connected in star.(it means that the motor is designed to be connected in delta only)
A star configuration of the windings in a 3-phase transformer or motor is where one end of each winding is connected to form a star or 'Y' pattern and the other ends are each connected to one of the three separate lines of the incoming 3-phase electrical service.A delta configuration is when each phase winding of a three phase transformer or motor is connected to its two adjacent phase windings to form an arrangement that looks like the Greek letter delta - or triangle - and then each point of the triangle is connected to to one of the three separate lines of the incoming 3-phase electrical service.To be able to wire a 3-phase transformer or motor either in star or delta, all 6 ends of the three sets of coils, called "windings", have to be exposed with suitable connection terminals.The windings are often labelled A1, A2, A3 and B1, B2, B3, where "1", "2" and "3" denote the separate phase windings and "A" and "B" denote the beginning and end of each winding.Another way of describing it is to say that the separate windings can be labelled:Winding 1: A1 B1. Winding 2: A2 B2, Winding 3: A3 B3.In star configuration either all the A's or all the B's are connected together and the 3-phase supply (consisting of three separate "phase lines" labelled L1, L2, L3) is connected to the remaining three connectors. For example, if you connect B1 to B2 and B2 to B3 to form the center of the "star" then you must connect supply L1 to A1; supply L2 to A2 and supply L3 to A3.In delta configuration, connect B1 to A2, B2 to A3, B3 to A1. (If you draw that out as a schematic diagram, it will be a triangle.) Then connect supply L1 to A1; supply L2 to A2 and supply L3 to A3. (Exactly the same as the supply lines were connected before, for the star configuration.)For more information see the answers to the Related Questions shown below.
There is no 'equivalent resistance' for three resistors connected in star.
no but star wars the force unleashed can you be connected to star wars the force unleashed III