What should be done in this situation is to change out the two blade receptacle to a three blade receptacle. Depending on how old the house wiring is, will depend on whether there is a ground wire in the two wire cable that the house was wired with. It sounds like the old two blade receptacle is worn out and it is the looseness between it and the adapter that is causing the problem. A room heater can be about 1500 watts and that adjusts to 12.5 amps that is heating up and melting your adapter. A new three blade receptacle will be tighter and it will not heat up. If there is a ground wire in the back of the receptacle's junction box attach it to the new receptacle. If there isn't a ground wire in the junction box, replace the receptacle anyhow, it will be much safer that the set up that you have now.
The Receptacle of a flower is the bottom of the flower. It holds everything together. reproductive parts of a plant. Receptacle is female
The new receptacle has to be a GFCI receptacle. Try and locate the inside junction box on the outside of the house. The back of the old receptacle should have a 1/2 inch knockout in it. Remove it. Drill through the KO hole right through the siding to the outside. This will be the center of the new outside GFCI receptacle's junction box. Cut a new EZ box into the outside siding. Feed new wire 2C-#14 from the old box to the new box. Terminate both ends and replace covers. The new outside receptacle will need a weatherproof receptacle cover plate.
No. To prevent this sort of thing from happening, the 277 volt device and receptacle is physically larger that a 240 volt receptacle and will not fit in a regular receptacle junction box. For a 277 volt system the proper size junction boxes have to be purchased.
No, the receptacle needs the screws in place to complete the bond between the metal component of the receptacle to the metal component in the receptacle's junction box. This bond is entirely separate from the grounding of the receptacle.
If the 2 hot wires are connected to either side of a receptacle, you have a 240v receptacle (assuming it's in the US). This is typically done for window air conditioners. But code requires that the receptacle have a different configuration than other receptacles in the building so you don't run the risk of plugging in a 120v device into a 240v receptacle.
A pan is a wide flat object used for cooking food within the house, or the contents of such a receptacle.
A pan is a wide flat object used for cooking food within the house, or the contents of such a receptacle.
Yes, there is no reason why this can not be done. In fact a benefit of this is that every receptacle downstream from this new receptacle will also be protected by the GFCI receptacle.
the same : receptacle
What should be done in this situation is to change out the two blade receptacle to a three blade receptacle. Depending on how old the house wiring is, will depend on whether there is a ground wire in the two wire cable that the house was wired with. It sounds like the old two blade receptacle is worn out and it is the looseness between it and the adapter that is causing the problem. A room heater can be about 1500 watts and that adjusts to 12.5 amps that is heating up and melting your adapter. A new three blade receptacle will be tighter and it will not heat up. If there is a ground wire in the back of the receptacle's junction box attach it to the new receptacle. If there isn't a ground wire in the junction box, replace the receptacle anyhow, it will be much safer that the set up that you have now.
Characteristics of a receptacle is the rating in amps and the pin configuration, which govern the use that the receptacle is approved for.
I don't know what receptacle means.
It is spelt correctly in the question (receptacle).
we used a receptacle to hold the cookies.
No, pull in a separate feed for the single phase receptacle.