The use of armoured cable is determined by the application that needs an electrical source of voltage. It is a metal sheath cable classification. Armoured cable is used in applications that need mechanical protection usually below a certain elevation. Armoured cable is also usually used on surface wiring. If you have access to an electrical code book there is a whole section on armoured cable. In the CEC the section about armoured cable starts at 12-600 to 12-618.
Copper xlpe armoured cable
If you are referring to an 11-kV underground cable, these are normally armoured and, in the case of older cables, have a lead sheath to prevent moisture ingress into the cable. The lead sheath and metal armour are earthed to ensure that, in the event of mechanical damage to the cable, there is a low-resistance path back to the source to sufficient earth-fault current flows in order to operate the circuit's protective system. Overhead lines do not normally have a separate earth conductor.
In a HT cable there are 2 layers of semiconductor one on the conductor and second on the XLPE insulation. As we know semiconductor behaves as conductor when temperature rises. So when the HT cable is on load its conductor temperature rises due to this the semicon layer which is on conductor behaves like conductor and as a result overall cross section area is increased. now the second semicon layer which is over XLPE on temp rise behaves as conductor and used for dessipating heat out of conductor as the cable heat due to load.
Armored electrical cable contains insulated electrical service wires protected by a flexible steel covering. Unarmored electrical cable has no protective flexible steel covering, its covering is made of plastic.
The use of armoured cable is determined by the application that needs an electrical source of voltage. It is a metal sheath cable classification. Armoured cable is used in applications that need mechanical protection usually below a certain elevation. Armoured cable is also usually used on surface wiring. If you have access to an electrical code book there is a whole section on armoured cable. In the CEC the section about armoured cable starts at 12-600 to 12-618.
You have to be specific. whether the conductor is aluminum or copper. Current carrying capacity will be different for these two types. Copper cable can take more load than aluminum cable for same diameter.
Copper xlpe armoured cable
Yry means copper round armoured cable
The advantage of using armoured cable over rigid conduit systems is the flexibility of the cable. There are some situations where conduit can not be bent into the shade needed to make a proper connection to a device. Because of the flexibility if the armoured cable it can be used instead to make a presentable looking job.
If you are referring to an 11-kV underground cable, these are normally armoured and, in the case of older cables, have a lead sheath to prevent moisture ingress into the cable. The lead sheath and metal armour are earthed to ensure that, in the event of mechanical damage to the cable, there is a low-resistance path back to the source to sufficient earth-fault current flows in order to operate the circuit's protective system. Overhead lines do not normally have a separate earth conductor.
SWB - Steel Wire Braid
The correct answer is....80-conductor IDE ribbon cable.
2 conductor round cable 2 conductor twisted cable
yes, but picture can not be enclosed here
Copper XLPE Armoured Power Cables.
The radius of the curve of the inner edge of the bends shall be at least 6 times the external diameter for armoured cable.