Depending on the connection this scenario could happen. The 240 volt heating element of a dryer is connected to the two outside terminals on the dryers terminal strip. Also in this circuit is a thermal cut out that will open the circuit should the internal mechanisms of the dryer get too hot. The motor connection and the controls of the dryer are 120 volts. This means that the voltage is obtained from one of the 240 volt legs and the neutral connection on the dryers terminal strip. This connection is in between the two outside 240 volt connection points on the terminal strip. On a four wire dryer cord the fourth wire is the ground and should go directly to the chassis lug on the dryers frame. Turn off the breaker or unplug the dryer from its receptacle and check your wiring. Red and black wires on the outside terminals on the dryers terminal strip. It makes no difference whether red is on the left or right terminal. The white (neutral) wire is on the terminal between the two red and black or black and red wires depending on how you placed them on the terminal strip. The ground wire of course will be connected to the frame of the dryer. If this is the way the connections are made inside of the dryer it should work. If any work has been done on the wall receptacle make sure that the wire on the receptacle match the wiring inside the dryer.
It depends on the model, if the hair dryer is a 1500 watt hair dryer, then it uses 1500 watts on high heat. If the hair dryer is a 2000 watt hair dryer, then it uses 2000 watts on high heat. Hair dryers come in all different size wattage, so it depends on the size wattage of the dryer. Most hair dryers are 1500 watts.
The dryer is going to heat up enough to dry the clothes and that's all it takes for the dryer sheets to work.
Yes, and not only heat but it does produce carbon monoxide also as a by product of combustion
Electric dryers typically are 220 volts and need a 30 amp, 2-pole circuit breaker. A 15 amp breaker would quickly trip if overloaded with a dryer. You may need a wiring upgrade (to 10 gauge) and a new 2-pole breaker for 30 Amps. You should also not be using two separate breakers for one 220 volt circuit; they should be either one unit or two that have their handles mechanically connected together. Hire an electrician.
The wire will heat up and melt and the battery may be damged.
Sounds like the motor is bad or the motor bearings are bad. This will create more resistance and will therefore create more current in the circuit. More current in the circuit will cause the overload to trip. This is for safety to prevent excess heat building up in the circuit which could cause a fire.
Replace the heating coil, now the dryer is not coming on when pressing the start button
who invented the clothes dryer that used heat from the stove
It could be that the bathroom circuit simply has more on it so the hair dryer is pushing the circuit beyond its limit. In a typical bathroom, properly wired, this would not be the case. But if there are lights on the circuit other than in the bathroom (it would take a lot of lights for this to be a problem), or if there is a source of heat in the bathroom that is on, this may be where your problem is.
filter dryer
The Kenmore Gas Dryer will not heat and dry clothing.
Electricity in electric circuits produce heat and when a circuit goes wrong the heat can escalate to the point where it causes combustion in the materials adjacent to it. This causes fires.
G T Sampson invented the clothes dryer
A hair dryer
a blow dryer
Heat energy
there are several reasons, an easy one to check is the breaker or fuse panel if one side of the breaker has tripped(not completely unheard of) or if one fuse has blown the dryer may still run but not heat. there are also several safeties in the electrical circuit that fail the element only and will allow the motor to run but should be attended to by a qualified individual.