Best Answer

A pressure gauge is attached to the proper fitting on a bench with valves and tubing. A known weight pressurizes a piston. That pressure goes to the gauge being calibrated and the N.B.S. certified gauge. The two are compared at several points called out in the test procedure. Adjustments are made to the mechanical linkage between the gauges internal tube and the indicator needle to make it read within an allowable percentage of deviance.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

12y ago

simply by using HART by setting LRV and URV.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is the calibration of the pressure instrument?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is the calibration of an ammeter?

calibration of an ammeter is done in order to standardise the instrument,and rectify the errors present in the instrument, if any.


What is an absolute instrument?

An absolute instrument is an instrument whose calibration can be determined by means of physical measurements.


What is the calculation for the calibration of a Level instrument displacement type dry method?

How to find out the calculation for dry calibration of a level instrument used on the top of the tank? How to calibrate level instrument with the help of weights?


How do calibration of pressure transmiter?

The pressure transmitter should only be calibrated if the individual knows what they are doing. The calibration of the pressure transmitter needs to be done on the line of pressure.


What is calibration of instrument?

To know about the error, quality, performance of every instrument calibration is an essential part. A standard calibrator is required for this process to calibrate that Instrument. That calibrator is also Calibrated and standardised by National or International Standard.


How do you detirmine the precision in an instrument?

By calibration in comparison to a standard one.


What is the basic calibration process?

The Basic Calibration Process is the process through which an instrument is calibrated, or set to a scale, during its manufacturing process - and it must be able to "hold a calibration."


Judgment criteria for whether an instrument needs calibration?

calibration criteria is depend on instrument. if u r 1st criteria is for 3 month and after 3 month instrument is properly working then second time you may be extended its for 6 month..


When calibration required?

Calibration is required during installation of new instrument to check whether the instrument works as per specifications or not. Calibration is required when instrument is shifted from one location to another. Calibration of instrument is done when instrument is used again after maintenance. Some instruments such as weighing balance are calibrated daily while some instruments or equipments such as HPLC, GC, etc., are calibrated or validated at specified interval as per standard operating procedure (SOP).


Why you use holmium filter for UV calibration?

to check the sensitivity of the instrument


What is the common formula used when checking equipment calibration?

sources used for instrument checking and calibration irradiation of other materials, and radiography called


What are Advantages of deflection type of instrument to null type of instrument?

The pressure gauge is a good example of a deflection-type instrument, where the value of the quantity being measured is displayed in terms of the amount of movement of a pointer. An alternative type of pressure gauge is the dead-weight gauge which is a null-type instrument. Here, weights are put on top of the piston until the downward force balances the fluid pressure. Weights are added until the piston reaches a datum level, known as the null point. Pressure measurement is made in terms of the value of the weights needed to reach this null position. The accuracy of these two instruments depends on different things. For the first one it depends on the linearity and calibration of the spring, whilst for the second it relies on the calibration of the weights. As calibration of weights is much easier than careful choice and calibration of a linear-characteristic spring, this means that the second type of instrument will normally be the more accurate. This is in accordance with the general rule that null-type instruments are more accurate than deflection types.