answersLogoWhite

0

to remove the air bubble, which are made error in volume.

S.Kailash

User Avatar

Wiki User

11y ago

What else can I help you with?

Related Questions

What do you mean by sieve no10?

"Sieve no.10" usually refers to a specific mesh size in a sieve analysis used to determine the particle size distribution of a sample. In this case, "no.10" typically corresponds to a sieve opening of 2.00 mm. The sieve analysis helps in characterizing the size of particles in a material sample.


What is the conclusion of sieve analysis?

The conclusion of a sieve analysis is to determine the particle size distribution of a sample. This is achieved by passing the sample through a series of sieves with decreasing mesh sizes to separate and weigh the particles in different size fractions. The data collected from this analysis can be used to determine the uniformity of the sample and its suitability for various engineering applications.


Why air dried sample used in sieve analysis?

to remove the air bubble, which are made error in volume. S.Kailash


Is it possible to carry out a sieve analysis on a sample clay why?

Yes, it is possible to carry out a sieve analysis on a clay sample, but the results may be limited. Clay particles are very fine and can pass through standard sieves, making it challenging to accurately separate and measure them. For effective analysis, a hydrometer or sedimentation method is often used in conjunction with or instead of traditional sieve analysis to assess the distribution of clay particles. This allows for a better understanding of the particle size distribution in the sample.


What is the difference between a wet sieve and a dry sieve analysis?

A wet sieve analysis involves using water to wash finer particles through the sieve, while a dry sieve analysis does not involve any added moisture and relies on natural particle movement through the sieve openings. Wet sieve analysis is typically used for cohesive materials, while dry sieve analysis is more commonly used for non-cohesive materials.


Do discussion about sieve analysis?

Sieve analysis is a method that is typically used in civil engineering to determine the size of particles and how those particles are distributed. A discussion about sieve analysis could be conducted after using a series of sieves to filter out different particles of sand.


How is a sieve used in earth science investigations?

In Earth science investigations, a sieve is used to separate soil or sediment samples by particle size. By passing the sample through different sized mesh screens, researchers can analyze the distribution of particles and classify the sample according to granular size fractions. This helps in studying soil composition, sediment transport, and understanding geological processes.


What are the applications of sieve analysis?

A sieve analysis test is a procedure to separate fine material from course material by means of a series of woven or perforated surfaces. The proportion of different size particles are recorded. This record is the conclusion of the analysis. Art Gatenby agatenby@cscscientific.com


Why soil samples need to be sieve using 2 mm?

Sieving soil samples using a 2 mm sieve helps to remove larger particles, such as rocks and debris, which can affect the accuracy of soil analysis. It ensures that the sample is uniform and allows for consistent test results. Additionally, the 2 mm sieve size is commonly used in soil testing protocols to standardize sample preparation.


A sample of something used in a lab for a study or analysis?

Specimen


What is sample of something used in a lab used for study or analysis?

specimen ... dissection


What is a sample of something used in a lab used studying or analysis?

specimen ... dissection