answersLogoWhite

0

That is only partially true. Legally you must repair the leak before adding refrigerant. You do not have to remove the Freon and recharge it with fresh Freon. However, this is what I would do if it were my car. I am assuming this is a 1996 or older vehicle which contains Freon (R12). I would have them remove all the R12, and give me credit for what they recover. R12 is very expensive, so don't give it away. I would then have the leak repaired and convert the vehicle to R134a. If it is newer than 1996, just repair the leak and recharge the system. You might want to go to a different repair shop, as what they are telling you is only half true. I would not trust this shop.

User Avatar

Wiki User

17y ago

What else can I help you with?

Related Questions

What causes fractionation to happen in certain blends of refrigerant?

what causes fractionation to happen i certain blends of refrigerants


What causes fractionation to happen in a certain blends of refrigerant?

Fractionation occurs in certain blends of refrigerants due to the different boiling points of the individual components in the blend. As the refrigerant evaporates or condenses during the refrigeration cycle, the refrigerant components can separate based on their boiling points, leading to changes in the composition of the refrigerant blend and potentially impacting system performance.


What does all near-azeotropic refrigerant blends exhibit?

near-azeotropic refrigerant blends all exhibit some .A )temperature glide and fractionation .B)oil problems .C) high boiling points .D)low condensing pressures


What is the difference between azeotropic refrigerant and zeotropic refrigerant?

Azotropic will only have one boiling or condensing point for each system pressure negligible fractionation or temperature glide will occur Zeotropic will have a range of boiling and condensing points for each system pressure noticeable fractionationand glide will occur.


Define a zeotropic refrigerant blend and give an example?

In a zeotropic blend, the blends boil out at different temperature but at the same pressure. typical example is R704


What are Two or more refrigerants blended together to create another refrigerant?

Two or more refrigerants blended together to create another refrigerant are known as refrigerant blends. These blends are formulated to optimize performance characteristics such as efficiency, stability, and environmental impact. Common examples include R-410A, a blend of R-32 and R-125, and R-407C, which consists of R-134a, R-125, and R-32. Blending can help achieve desired thermodynamic properties while also addressing issues like ozone depletion and global warming potential.


What are three major types of consonant blends?

The three major types of consonant blends are initial blends (blends at the beginning of a word, e.g., "bl"), final blends (blends at the end of a word, e.g., "st"), and medial blends (blends in the middle of a word, e.g., "sk").


What is the Zeotropic Refrigerant?

A zeotropic refrigerant is a type of refrigerant blend that has a varying composition of components, which means it does not evaporate or condense at a constant temperature. Instead, it exhibits a temperature glide during phase changes, where the temperature changes gradually over a range rather than at a single fixed temperature. This property can enhance efficiency in certain cooling applications but may also complicate system design and operation. Common examples of zeotropic refrigerant blends include R-407C and R-410A.


What is the underline and blends and digraph blends for the word drum?

Dr


What companies make chicory coffee blends?

Emeril's can make chicory coffee blends. Cafe DuMonde can also make chicory coffee blends. Luzianne is also another company which can make chicory coffee blends.


Define a near-azeotropic refrigerant blend and give two examples.?

a blended refrigerant with less than 10F temperature glide, 41oA and 404A are examples.


What is the difference between azeotropic and near-azeotropic refrigerant blends?

Azotropic will only have one boiling or condensing point for each system pressure negligible fractionation or temperature glide will occur Zeotropic will have a range of boiling and condensing points for each system pressure noticeable fractionationand glide will occur.