answersLogoWhite

0

My horn in my 1998 Malibu kept blowing. I took the relay out to shut the horn off. I had a diagnostic check done because this is the second time this has happened. The first time, a new relay worked. This time, replacing the relay did not solve the problem. Turns out that the horn button located within the steering wheel is stuck. Unfortunately, this is part of the air bag mechanism and will be quite costly to replace.

I am attempting to find directions to bypass the horn with a Horn Button and Wiring kit so I have a working horn to pass inspection.

User Avatar

Wiki User

16y ago

What else can I help you with?

Related Questions

Why would a car horn be blowing on its own on a ford 1998 windstar minivan?

The horn button or relay could be stuck. The most common cause is the relay sticking closed, as opposed to the button.


What would cause my 2002 Pontiac Montana's horn to start blowing for no cause?

Faulty horn switch, faulty horn relay, or a short to power somewhere in the wiring. Power should be constant at the 30 pole of the relay, and should only be present at the 86 pole when the horn switch is depressed.


How to stop horn from blowing constantly?

Most likely a short between the horn relay and the horn switch in the steering wheel.


How do you disconnect a car horn?

The easiest two ways are to either remove the fuse, or remove the relay. If the horn is stuck blowing then the relay is probably bad.


What would cause 2002 Malibu horn stop working?

could be horn relay in underhood fuse box. or bad horn..


The horn on your Chevy cav 1998 is stuck what needs to be replaced to fix it.?

The most common problem for a stuck horn is actually a stuck horn relay. Remove the relay and the horn should stop blowing. the relay may be hot from being stuck. replacing the relay should fix the problem.


How do you stop the horn from randomly blowing 98 Dodge Grand Caravan?

The horn relay may be faulty. Try replacing that.


2001 Saturn constant horn blowing?

Typically, that problem would only be caused by a faulty horn relay or a damaged horn contact switch inside the steering column. A frayed wire that rubs on a metal part of the vehicle. Since the relay is the easiest part to test, remove the relay and replace it with a similar relay FOR TEST PURPOSES ONLY. If the horn works properly with a replacement relay, put the relay you used for testing back and purchase a new horn relay. If the test relay left the horn ON, you probably have a damaged horn contact switch, in which you will need to replace the faulty component.


What would cause the horn to stop working?

bad ground or wiring, bad switch/button, bad horn, bad horn relay, fuse.


Why would the horn on a 1996 Saturn start blowing without anyone in the car?

The wire to the relay grounded somewhere. Take it to a garage to get it checked out.


Can a faulty horn relay cause the horn to stick?

Yes, a faulty horn relay can cause the horn to stick. If the relay is stuck in the "on" position due to internal failure, it may keep the circuit closed, resulting in the horn sounding continuously. Additionally, a malfunctioning relay may not disengage properly when the horn button is released, leading to the same issue. Checking the relay and replacing it if necessary can resolve the problem.


Why does the horn on a 1997 Kia Sportage work sometimes and then stop?

There are sever possibilities to the horn not blowing consistently. The horn relay or horn button are the most common followed by a loose wiring connection or a defective horn.