You need a chart which identified the relationship between the ambient air temperature and the pressure, as well as a manifold gauge set.
Suction pressure
I guess that would be measured in units of pressure: Pascal = Newton/meter2.
Read the charging chart specific to the unit. Not all 410A machines will operate at identical pressures in identical conditions.
pound per square inch
60psi
The suction pressure of an R22 unit on an 83-degree day will vary depending on factors such as indoor temperature, coil condition, and humidity levels. A typical range for suction pressure on an R22 unit could be around 60-70 psi on an 83-degree day. It's important to refer to manufacturer specifications and consider other system parameters for an accurate assessment.
The suction pressure for a heat pump at an outside temperature of 34 degrees F will vary depending on factors like the system's design, refrigerant type, and load conditions. It's best to refer to the manufacturer's specifications or consult with a qualified HVAC technician to determine the appropriate suction pressure for your specific system.
IT COULD THAT YOUR SYSTEM IS EITHER OVERCHARGED OR UNDER CHARGED. ALSO CHECK YOUR FURNACE FILTER.AND MAKE SURE YOUR OUTDOOR UNIT is clear of dirt and obstructions. --------------------------------------------------------------- There are several reasons for a compressor to overheating High compression ratios are the result of either lower than normal suction pressures or higher than normal discharge pressures. Changes in suction pressure will affect the compression ratio more rapidly than changes in the discharge pressure. For this reason, it is important to keep the suction pressure at its highest possible value. Causes of low suction pressure can include incorrect sizing of components, misadjusted or defective metering devices (TXVs), loss of refrigerant charge, plugged driers or strainers, and excessive suction line pressure drop. Although not as sensitive to change as the suction pressure, the discharge pressure can still greatly affect the compression ratio. Keeping the discharge pressure within normal operating conditions is still important. Causes of high discharge pressure can include dirty condensing coils, undersized discharge line, a blockage or recirculation of condenser air, erratic condenser fan operation, refrigerant overcharge, noncondensibles in the system, and an undersized condenser.
With the unit running, front seat the liquid line valve and monitor the pressure. Once you have the unit in a vacuum, front seat the suction side and cut the power to the unit.
Pressure = Force normal to the surface per unit surface area The SI unit for pressure is N/m^2
what is the charging schedule for a 2 1/2 ton unit 70degree ambient temp what is the suction pressure supposed to be
The suction line pressure on a 3-ton 410A unit at 50 degrees Fahrenheit will depend on various factors such as the indoor and outdoor conditions, the type of system, and the specific operating parameters. In general, the suction line pressure can be expected to be around 70-90 psi at 50 degrees Fahrenheit for a properly functioning system. It's important to consult the manufacturer's guidelines or a professional technician for more accurate information.