What is the airflow velocity within a branch duct if the flow rate is 175 cfm and the duct is 12 inches high by 18 inches wide?

answer is


What is the formula for duct sizing?

To calculate the formula for duct sizing divide the room load by the whole house load. Next multiply those results by the equipment CFM.


How do you calculate duct size with area given?

if the area given is 100 square inches you can use 10" by 10" duct due to a black art known as aerodynamics or compressible fluid flow, you will get the same back pressure in a 10" diameter round duct and a 2" x 50" duct considerably more back pressure a nice manufactured 90 will take as much back pressure as 50' of duct a tight curved 90 will take as much as 100 feet of duct fans have a curve that goes from maximum cfm at no pressure to minimum cfm at max pressure the fan will require the most power when cfm * pressure is highest simple as rocket science i guess


To increase air flow between rooms should vent be installed on the upper or lower part of a door?

It depends. If your bedroom has a supply AND return duct, then no. If there is only a supply duct, and you shut your bedroom door, this pressurizes the bedroom and limits the CFM delivered into the bedroom. A room to room vent or duct would equalize this pressure and allow maximum CFM to be delivered from the central air/heat system.


How do you calculate the tonnage of AHU?

You need 350 to 400 cfm per ton (12,000 btu) of cooling. So, divide your cfm by 400. For example, a 1200 cfm blower on an air handler could handler up to 3 tons. All calculations depend on your duct being the proper size for the equipment.


What is the formula to convert FPM to CFM?

If you know the FPM and you know the area of your flow say duct work (20"x20")...first convert your area 20*20=400 in2 to Ft220"*20" = 400in2 400in2/144 = 2.7777Ft2Now that you know the area in Ft2 you can use the equation [ FPM*area(ft2) = CFM ]if your FPM is 500 and we use the 20"x20" duct then500fpm * 2.777Ft2 = 1388.5 cfm


Who are the best HnS players?

the best HnS players are: -cFm |K[a]YD!zZzZ -cFm | TaCo -cFm | KillaKount *dankHnS|DADDADADA-cFm| the "-cFm|" clan is the clan u want to be in if u want to be up there with one of the best.-cFm| stands for Come Find Me -cFm| IS HNS!


What duct size should you use to move 2000 cfm of air?

To determine the appropriate duct size for moving 2000 CFM of air, you can use the Air Flow Velocity formula, which suggests an optimal air velocity range of 600 to 900 feet per minute (FPM) for residential systems. Using an average velocity of around 800 FPM, a round duct size of approximately 14 inches in diameter is recommended. For rectangular ducts, a size of about 10 inches by 14 inches is typically suitable. Always consider local codes and specific system requirements when finalizing duct sizes.


What does air-conditioning abbreviation 'cfm' means?

cfm stands for cubic feet per minute - this is a term that describes the amount of air flow in duct work - it takes approximately 400 cubic feet per minute air flow per ton of air conditioning


'What is the formula to convert FPM to CFM?

To convert Feet Per Minute (FPM) to Cubic Feet Per Minute (CFM), you need to multiply the FPM value by the cross-sectional area of the duct or opening in square feet. The formula is: [ \text{CFM} = \text{FPM} \times \text{Area (sq ft)} ] Make sure to measure the area in square feet for accurate conversion.


What information can I find in an exhaust fan CFM chart?

In an exhaust fan CFM chart, you can find the airflow capacity of different exhaust fans measured in cubic feet per minute (CFM). This information helps you choose the right fan for your space based on its size and ventilation needs.


What is the recommended return air duct size for optimal HVAC system performance?

The recommended return air duct size for optimal HVAC system performance is typically 1 square inch per 1 CFM (cubic feet per minute) of air flow.