You will need to change the blower motor resistor by finding it near the air duct system. You will take the old resistor off and replace it the same way.
The blower motor circulates the air through the system.
You will need to locate a few wires that are located on a small plate between the heater and air system of a 2002 Kia Sportage. The resister pack rests there and can be removed and replaced to fix the blower.
the relays are behind the glove box. you have to take the glove box out to have access to the relay for the heating system
# Disable the airbag system before working # Remove the lower right dash insulator panel for access to the blower motor # Disconnect the electrical connector from the blower motor and remove the three screws from the blower housing # Pull the blower motor and fan straight down # To remove the fan from the blowr motor,use a narrow punch and tap the shaft out of the fan assembly.
No heat can be a clogged heater core or a thermostat stuck open. No low speed blower motor is a defective Blower Motor Resistor Pack. I suggest you drain and flush the cooling system with the heater set at hot. Replace the thermostat with the correct temp unit, pour in a 50/50 mix of antifreeze and distilled water, and bleed all air from the system.
A 1998 Cadillac Deville does not have a blower relay. The system has a fuse and a controller to feed power to the blower motor.
To replace the friction wheel on an MTD snow blower, you will need to disconnect the spark plug wire, remove the auger belt and pulley, then remove the wheel assembly. Install the new friction wheel by reversing the steps, making sure to adjust tension on the drive system properly. Refer to the snow blower's manual for detailed instructions.
Thermostat may be stuck open. Drain the system, replace the thermostat and fill with a 50/50 mix of the correct antifreeze and distilled water. Heater core may be clogged. Replace the heater core. Blend door be stuck. Blower motor may not be running. Repair the problem. Blower motor not working. Either the blower motor is defective, fuse is blown, or the resistor pace is defective.
to escape the internal air in the system to atmosphere
Check the fuses and blower relay. Also check to make sure that the replacement blower motor has not failed. If these items are good then the electrical system will need to be tested to see where the blower system is losing power.
The central heating system that involves a furnace and a blower is known as a forced air heating system. In this system, the furnace heats air, which is then distributed throughout the building via ductwork and a blower. This method is efficient for heating large spaces quickly and can also be used for air conditioning when paired with a cooling system.