AC discharge and suction lines are components of an air conditioning system. The discharge line carries high-pressure refrigerant gas from the compressor to the condenser, where it releases heat and condenses into a liquid. In contrast, the suction line transports low-pressure refrigerant gas from the evaporator back to the compressor, where it is compressed and cycled again. Proper insulation and maintenance of these lines are crucial for efficient system performance.

User Avatar

AnswerBot

2d ago

What else can I help you with?

Related Questions

Comparration diameter size of suction and discharge?

The diameter of the discharge line leaving the ac compressor would be smaller than the suction line, because the compressed gas in the discharge line is more dense.


High side is the suction or discharge?

Discharge side........


Where is low pressure AC port?

It will be on the suction line (larger of the lines) between the compressor and the evaporator.


Where is the suction side of a GM AC compressor?

The suction side of a GM AC compressor is located at the inlet port, where refrigerant vapor is drawn into the compressor from the evaporator. This side typically has lower pressure compared to the discharge side, which expels high-pressure refrigerant vapor. The suction line connected to this port is usually larger in diameter and may be insulated to prevent heat gain.


How do you change AC compressor on 2001 Navigator?

To change the AC compressor on a 2001 Lincoln Navigator, first, disconnect the battery and recover the refrigerant from the AC system using a recovery machine. Next, remove the serpentine belt and disconnect the electrical connectors from the compressor. Unbolt the compressor from its mounting bracket, remove the suction and discharge lines, then install the new compressor by reversing the steps. Finally, recharge the AC system with refrigerant and check for leaks.


Why is discharge line leaving outside unit cold on central ac?

The expansion device inside the outside unit expands the refrigerant gas and as a result, the discharge lines chills


Where is suction and discharge s?

Answer: The terms suction and discharge are the terms refer to hydraulics. In hydraulics if the the liquid has to be lifted or pumped to the usage area the hydraulic pump will be used . This pump will have to functions that is first suction to lift the fluid and the discharge or delivery . The familiar words in pair are lift and discharge; suction and discharge. The specification of pump for these terms are suction head and discharge head.AnswerThe suction pressure refers to the pressure of the referigerant being "sucked" back into the compressor. The suction pressure is a critical variable in ensuring the accuracy of the refrigerant charge, along with the tepmerature of that line as well. The "superheat", or heat added to the vapor in that line can be monitored in this manner.You have not mention which suction pressure... Actually Where ever the suction is presented that pressure is called suction pressure.... and suction pressure in practical cases normally always less that atmospheric pressure and in case of delivery pressure it is oppositeSaying that suction pressure is " the pressure of the referigerant being "sucked" back into the compressor " is not accurate.Simply , the suction pressure of a pump is the absolute pressure of a fluid , measured at the inlet of the pump ( in your answer , the pump is the compressor , and the fluid is whatever refrigerant. )The discharge pressure , is the absolute pressure of the liquid measured at the outlet of the pump.Obviously, the discharge pressure is usually bigger than suction pressure.


What is a pressure differential?

its pressure between suction and discharge flow...


What can cause ac compressor to start and stop?

Dirty condenser coils. Blocked suction lines. Low refrigerant charge. Incorrect suction line size. Too much refrigerant. Electrical problems. Contaminants in the system. Insufficient oil lubricant.


How long the minimum discharge and suction pipe must be For small airconditioning unit eg1-2 TR?

how long discharge and suction pipe shuold be for small 1-2 TR airconditioning units?


How long the minimum discharge and suction pipe must be For small airconditioning unit eg1 2 TR?

how long discharge and suction pipe shuold be for small 1-2 TR airconditioning units?


What is the definition of reciprocating pump?

a pump consisting of a piston that moves back and forth or up and down in a cylinder. The cylinder is equipped with inlet (suction) and outlet( discharge) valves. On the intake stroke, the suction valves are opened, and fluid is drawn into the cylinder. On the discharge stroke, the suction valves close, the discharge valves open, and fluid is forced out of the cylinder.