Can you mix R22 with R404A?

No


Can you put r404a into an air conditioner designed for r410a?

No


Is R404A freon compatible with R409a?

No r404a is not compatible with r409a, r134a and 404a use the same lubricates and are compatible but r409a use a different lub making them incompatible


Can i replace r404a with r134a?

No, you cannot directly replace R404A with R134A, as they have different properties and applications. R404A is a blend designed for low-temperature refrigeration, while R134A is typically used in medium-temperature applications, such as automotive air conditioning. Using R134A in a system designed for R404A could lead to inefficiency, inadequate cooling, and potential damage to the system. Always consult with a professional technician before making refrigerant changes.


Can you receive r404a in to a empty r22 cylinder?

No. There'll still be residual traces of R22, even if the cylinder is empty, and it won't blend with the R404A. Furthermore, the R22 cylinder will be labeled as such, and it's actually a crime to have such cylinders improperly labeled.


What type of refrigerant is used in a ac?

R134A, R22A, R404A, R410A and many more


How much does R404A refrigerant cost per pound?

Depends who you purchase it from and in what quantity.


What should the pressure of R404A to recharge refrigerator?

The pressure of R404A for recharging a refrigerator can vary depending on the specific refrigerator model and the manufacturer's recommendations. However, typical recommended operating pressures for R404A refrigerant in a refrigerator range from about 160 psi to 250 psi on the low side and from 250 psi to 350 psi on the high side. It's crucial to consult the refrigerator's instruction manual or a qualified technician to ensure the correct pressure levels are maintained during recharging.


What is compatible with R404?

R404A is a refrigerant commonly used in medium and high-temperature refrigeration applications, such as in commercial refrigeration and air conditioning systems. It is compatible with various oils, including polyolester (POE) oils, which are commonly used with HFC refrigerants. Equipment designed for R404A should be constructed from materials resistant to chemical breakdown and should ensure proper seals to prevent leaks. Additionally, R404A can typically be used with systems designed for R22, but retrofitting may be required.


How do you charge an R404A unit?

Charging an R404A unit involves connecting a charging hose from a refrigerant cylinder to the low-pressure side of the system. The refrigerant is then added slowly, while monitoring the system's pressure and temperature to ensure proper charging levels are reached. It is recommended to consult a professional technician to ensure correct charging procedures are followed.


What amount of superheat in R404A?

The recommended amount of superheat for R404A typically ranges from 5 to 15 degrees Fahrenheit (about 3 to 8 degrees Celsius) for most refrigeration applications. This ensures efficient operation and helps prevent liquid refrigerant from returning to the compressor, which can cause damage. However, the exact superheat setting may vary based on the specific system design and operating conditions. Always refer to the manufacturer’s guidelines for optimal performance.


Why are there more safety precautions with r410a than with other popular refrigerants like r22 and r404a?

The pressure of R-410A is significantly higher than other refrigerants R-22 and R-404A. This does not mean that R-410A, or equipment containing R-410A is unsafe. It does mean that technicians must use AC equipment; cylinders and service tools have been re-engineered to handle these higher pressures.