It can be at any pressure less than the main steam pressure.

I've operated steam systems with condensate tanks at widely varying pressures. The pressure a condensate tank, (which condenses some steam, but typically takes returns from steam traps) is wholly dependent on the system is installed in. Some heating system condensate tanks are designed to handle no more than 30 psig (minimum design requirement) yet take condensate at 1 or 2 psi from the steam traps. Other high pressure production lines operating at 50 - 100 psig could discharge to a tank at 50 - 100 psi, though the actual pressure would be reduced by the length of pipe transferring it to the tank. And the highest pressure I've operated a condensate system at was 600 psig, the steam system drew the steam for process from an extraction stage on the turbine at nominally 600 psi, though at low loads it was typically a much lower pressure.

User Avatar

Wiki User

12y ago

What else can I help you with?

Continue Learning about Chemical Engineering

Does condensate return need to go through a flash tank prior to a DA tank for a steam boiler system?

In a steam boiler system, condensate return does not necessarily need to go through a flash tank before entering the Deaerator (DA) tank. However, using a flash tank can be beneficial in recovering some heat and reducing pressure, allowing for more efficient use of the condensate. This process can help minimize the amount of makeup water required and improve overall system efficiency. Ultimately, whether to include a flash tank depends on the specific system design and operational requirements.


How you can convert natural gas condensate to natural gas volume equivalent?

Veq = 133000*(Condensate specific gr/Mol wt of condensate) in SCF/STB Where, Mol wt of condensate = 6084/(API-5.9)


What is the basic operating principle of a flash tank?

What You Should Know About Flash Tanksby J. E. TROCOLLI • Sarco Co., Inc. • Allentown, PA (Actual Specifying Engineer/71)High-pressure steam systemsrequire flash tanks -here is a guide to determining sizesCondensate temperatures in high-pressure steam systemsgenerally are only slightly less than the saturatedtemperature of the steam. When hot condensates are dischargedinto lower-pressure areas, condensate temperatureimmediately drops to the saturated temperature ofthe low-pressure area. As the result of the drop in temperature,heat released evaporates a portion of the condensate,generating flash steam.To return condensate to the boiler or to discharge it tothe sewer, it is necessary to separate flash steam fromthe condensate. This is accomplished by discharging condensatethrough steam traps into a vented tank, referredto as a flash tank.Flash steam produced in the flash tank may be ventedto the atmosphere or piped to a low-pressure main. Condensateremaining may then be returned to the boiler ordischarged to drain.Tanks must be large enough to ensure dryness of thereleased steam and to avoid carryover by the steam ofwater in droplet form. When using horizontal flash tanks,the required area is found by multiplying the diameter ofthe tank by its length. This measures the tank's capacityto handle condensate. Table 1 illustrates the required areafor each 1,000 lb. of condensate/hour with varying steamand flash pressures.How big a tank?Problem:An absorption machine condenses 12,000lb. of steam/hr. Assuming the flash tank is vented to theatmosphere, determine the size of the flash tank requiredwith a steam pressure of 12 PSIG.Solution:Enter table 1 at 12 PSIG steam pressure,moving horizontally to 0 PSIG. Find .75, which is the numberof square feet required for each 1,000 lb. of condensate.Since 12,000 lb. of steam are generated, it may bedetermined that by multiplying 12 x .75, 9 sq. ft. of surfacewill be required, or that the diameter of the tank infeet times its length in feet must equal 9. Thus, a tank 2ft. by 4.5 ft. may be used.Problem:A dryer operating at 100 PSIG condenses18,000 lb. of steam/hr. The flash tank is to discharge itsflash into a 5-PSIG heating main. Determine the size ofthe flash tank required.Solution:Again, using table 1, enter at 100 PSIGinitial pressure. Move horizontally to the 5-PSIG columnand find 1.92.Then:18 x 1.92 = 34.6 sq. ft.A flash tank 4 ft. by 9 ft. will be satisfactory for theapplication.Sizing vent linesIf flash steam is to be discharged to the atmosphere,a properly sized vent line must be provided. To determinethe proper size, first find the area of the flash tank,using the method described above.Problem:Determine the size of the vent line usingtable 2. If, as in the first problem, tank size is 2 ft. by 4.5ft. (9 sq. ft.), refer again to table 2, where 9 sq. ft. falls on7.4-to-12 line. For this range, a 2-in. vent line would besatisfactory.Problem:Determine the size of the vent line if theflash tank size is 4 ft. by 9 ft. or 36 sq. ft. In table 2, 36 isin the 27-to-36 line, and, in this case, a 31/2 in. vent wouldbe needed.Figure 1 shows a typical flash-tank piping diagramin which the flash is discharged to the atmosphere.If it is desired to utilize the flash steam by dischargingit into a low-pressure main, refer to figure 2. In thisinstance, it will be necessary to properly size the lineconnecting the flash tank to the low-pressure main.Using table 3, determine the percent of flash. Multiplythis percentage by the condensate load in lb./hr. todetermine the number of pounds of steam that are flashed.Determine what steam velocity will be acceptable in theline. If a low noise level is desired, a relatively low velocitymust be selected - 4,000 to 6,000 FPM.Where noise is not a factor, a velocity of 12,000 FPMor higher may be used. After velocity has been determined,the required pipe size can be found in table 4.Problem:10,000 lb./hr. of condensate is dischargedinto a flash tank from a 125-PSI steam system. Flashsteam is to be piped into a 10-PSIG low-pressure heatingmain. Determine the size pipe required for connectingthe flash tank to the steam main.Enter table 3 at 125-PSI initial pressure. Move horizontallyto the 10-PSIG column and find 12.2 percentflash. Then the amount of flash steam/hr. is found thisway:10,000 x 12.2 percent = 1,220 lb./hr.SECTION ENG - PAGE 0100FLASH TANKSTABLE 1 FLASH TANK IN SQ. FT. = DIAMETER x LENGTH OF HORIZONTALTANK FOR 1,000 LB. CONDENSATE PER HOUR BEING DISCHARGEDTABLE 2 VENT LINE SIZE TABLE 3 PERCENT FLASHFOR HORIZONTALFLASH TANKS½"FLASH TANKSTABLE 4 STEAM VELOCITY CHARTFORM FLASH TANKSRevised 4/04 SHIPCO® IS A REGISTERED TRADEMARK OF SHIPPENSBURG PUMP CO., INC.SHIPPENSBURG PUMP COMPANY, INC.,P.O. BOX 279, SHIPPENSBURG, PA 17257 • PHONE 717-532-7321 • FAX 717-532-7704 • WWW.SHIPCOPUMPS.COMPRINTED IN THE U.S.A. • BEIDEL PRINTING HOUSE, INC., 717-532-5063 PERMISSION TO REPRINT BY SPIRAX SARCO INC.Since low noise level is important, a velocity in the4,000 to 6,000 FPM range must be selected. Enter table4 at 1,220 lb./hr., moving horizontally to a flash-steampressure of 10 PSIG. Then move up to 4,000 to 6,000FPM velocity. Here, the chart shows that a 3-in. pipe willhandle about 6,000 FPM, or a 4-in. line would handleabout 3,500 FPM.When vent lines cannot be extended to dischargeoutside the buildings, it is important that the condensatebe cooled below the dewpoint to prevent the exhaustfrom condensing and wetting walls, machinery, floors andso on.Estimating temperatureSince the dewpoint depends on several factors, includingrelative humidity and temperature (which are variable),the temperature to which the condensate must becooled should be estimated for individual cases.The following is the recommended procedure:Calculate the size of the flash tank in the methoddescribed above:Estimate the dewpoint, assuming unfavorable conditions,and, when making the estimate, take ventilation intoaccount - it is a factor in determining relative humidity:Once the dewpoint is known, estimate the quantityof cooling water that will be required and finally:Determine the pipe size and size of temperatureregulator valve required. A self-contained regulator witha normally closed valve to open when the temperaturerises is recommended. All such controls have an amplerange over and under the calibration point so that settingmay be adjusted after installation.Problem:Calculate the quantity of cooling water requiredto cool condensate in a flash tank vented to anenclosed space, assuming the following data:Steam pressure is 100 PSIG;Condensate is entering the flash tank at 1,550 lb./hr.at 335°F;Ambient temperature of the space into which ventdischarges is 75°F; andCold water temperature is 50°F.Assuming that ventilation at the above temperaturewill be sufficient to have not more than 70 percent relativehumidity, the dewpoint will be 64.5°F (determinedfrom psychrometric chart).To allow 1°F for safety, condensate should be cooledfrom 338°F to 63.5°F. When the installation is completed,further adjustment can be made by resetting the regulator.The heat to be extracted from the condensate is equalto:1,500 lb./hr. x (338-63.5)°F = 410,000 BTUHThe quantity of cooling water required:410,000 BTUH(63.5 -50)°F= 30,500 lb./hr.or 3,670 GPH = 61 GPMA 1.5-in. pipe to supply the water and a 1.25-in. temperatureregulator are recommended for this application.Flash tanks separate flash steam from the condensateby venting the flash steam to the atmosphere orpiping it to a low-pressure main, while returning the remainingcondensate to the boiler or discharging it to thedrain. If flash steam is discharged to the atmosphere, aflash tank and a properly sized vent line must be determined;if discharged to low-pressure mains it is necessaryto calculate the correctly sized line connecting theflash tank to the low-pressure main. Also, the proper temperaturefor cooling the condensate must be determinedfor projects in which vent lines cannot be extended todischarge outside the buildings.Different situations require individual solutions to determinethe correctly sized flash tank, connecting pipeand cooling temperature needed, but the calculation examplesoffered here provide the means to determine thenecessary installations and accessories required.Figure 1A typical flash tank pipingdiagram discharging to atmosphere.NOTE: Omit trap if condensate isdischarged into vented pump receiver.Figure 2A typical flash tank pipingdiagram with flash discharging to lowpressuresteam system.Figure 3This diagram depicts acombination flash tank installation withsubcooling condensate.VENTPRESSURERELIEF VALVEVENT IFDESIREDTO LOWPRESSURE MAINHIGH PRESSUREFROMCONDENSATEHIGH PRESSURESYSTEMFLASH TANKSTRAINERFLOAT ANDTHERMOSTATICTRAPFIN TUBECOOLING LEGREQUIREDTO LOW PRESSURERETURN LINE ORDRAINVENT TOATMOSPHEREHIGH PRESSUREFROMCONDENSATEHIGH PRESSURESYSTEMFLASH TANKSTRAINERFLOAT ANDTHERMOSTATICTRAPFIN TUBECOOLING LEGREQUIREDTO DRAINCONDENSATEFROM HIGHPRESSURESTEAM SYSTEMTEMPERATUREREGULATORSTRAINERCOLD WATERSUPPLYVENT TOT ATMOSPHEREWATER LEVELCOILDRAINTO SEWERFLASH TANKS


How does condensate return to a boiler?

Condensate is what you get when you condense steam (water) that was heated in a boiler to make the steam. I'm not sure what else you are looking for.


Why the steam inlet at the top and coolant circulation from bottom of the reactor why we can't use the glass lined reactors for alkali reactions?

In the PWR the top houses the steam outlet, not inlet, and coolant flow is applied to the pressure vessel inlet connections. A glass lined vessel would simply not be durable enough for a 40 or hopefully 60 year life. If it started cracking or peeling off, how would it be repaired?

Related Questions

Where is the inlet and outlet of your pressure tank?

A pressure tank for a pump & well potable water system only has one connection. To connect the pump and tank to your house's water inlet, simply connect the tank and pump together with pressure rated pipe, SCH 40 PVC works fine. In that line, cut in a TEE fitting, and from that T, connect the house inlet with a valve to shut the water off.


How do you calculate 25 bar steam condenstate pressure?

If the steam pressure is 25 bars the condensate pressure is at most 25 bars. Typically it is slightly less due to friction of the fluid passing through the steam traps. As the condensate approaches the condensate tank, where it is normally vented to atmosphere, the pressure decreases in the system to near atmospheric.


How do you pipe hydropneumatic tank?

To pipe a hydropneumatic tank, first ensure proper placement and support for the tank. Connect the inlet pipe from the water source to the tank's inlet fitting, ensuring it's properly secured and sealed. Install an outlet pipe leading to the distribution system, and include a pressure gauge and a valve for maintenance. Finally, connect a compressed air supply to the tank's air inlet to maintain the needed pressure for operation.


What does a residential water pressure tank installation diagram typically include?

A residential water pressure tank installation diagram typically includes the tank itself, pipes for water inlet and outlet, a pressure switch, a pressure gauge, and a relief valve.


How do you calculate conversion of steam to condensate?

To calculate the conversion of steam to condensate, you can use the formula: Steam Converted to Condensate = Steam Inlet - Steam Outlet This formula subtracts the amount of steam leaving the system (Steam Outlet) from the amount of steam entering the system (Steam Inlet) to determine the amount of steam that has been converted to condensate.


What are the components and functions of a well pressure tank diagram?

A well pressure tank diagram typically includes components such as the tank itself, a pressure switch, a pressure gauge, a relief valve, and a water inlet/outlet. The functions of these components are to regulate water pressure, monitor pressure levels, release excess pressure, and control the flow of water in and out of the tank.


What happens if a bladder is broke in pressure tank is?

depending on many different situations, your bladder in your pressure tank can be broke and it can still work if your pressure tank is vertical with inlet down and your bladder just has a hole or crack in it. Most of the times however with a damaged bladder the pre pressurized air inside the tank will over time leak into the water system and then your pressure tank will not work properly. Sometimes on pressure tanks that sit vertical and have a ruptured bladder the pieces of the bladder clog the inlet/outlet thus making the pressure tank fail and it can be a pain if its a bigger pressure tank to remove because it will not drain out the water. Most pressure tanks have a air inlet on top or opposite side of the water inlet/outlet and should always be precharged of air pressure psi depending on the amount of water pressure like example 15-18 air psi if water system is running at 55-60 psi. One way to find out if your bladder is broke or precharged in your pressure tank is to drain the water pressure out then put a air gauge on the air fitting of the tank and see if it has pressure.


How do you drain water tank to build pressure?

To drain a water tank to build pressure, first, turn off the power supply to the tank and close the inlet valve to prevent further water flow. Next, open the drain valve at the bottom of the tank to release the water, allowing it to empty partially or completely, depending on your needs. Once the desired level is reached, close the drain valve and reopen the inlet valve to refill the tank, which will help build pressure as the water heats up. Finally, restore power to the tank.


What is flash separation?

A flash separator consists of a vessel where the pressure is lower than the inlet stream. When the inlet stream enters the tank (which has a larger volume), the pressure may drop, as well as the temperature. When the pressure drops, the vapors dissolved in the liquid inlet will boil, "flash," into the vapor phase. Thus, the dissolved gases in the liquid are separated by "flashing" them.


What is the difference between back pressure steam turbine and condensate steam turbine?

In a back pressure turbine all available energy from the inlet steam is NOT used to generate power; steam exhausts at a tangible pressure and is then used for, usually, heating or chemical processing. In a condensing turbine, all the inlet steam does mechanical work right down to the lowest pressureafter which it is condensed in a heat exchanger


What is mean flash separator?

A flash separator consists of a vessel where the pressure is lower than the inlet stream. When the inlet stream enters the tank (which has a larger volume), the pressure may drop, as well as the temperature. When the pressure drops, the vapors dissolved in the liquid inlet will boil, "flash," into the vapor phase. Thus, the dissolved gases in the liquid are separated by "flashing" them.


Does condensate return need to go through a flash tank prior to a DA tank for a steam boiler system?

In a steam boiler system, condensate return does not necessarily need to go through a flash tank before entering the Deaerator (DA) tank. However, using a flash tank can be beneficial in recovering some heat and reducing pressure, allowing for more efficient use of the condensate. This process can help minimize the amount of makeup water required and improve overall system efficiency. Ultimately, whether to include a flash tank depends on the specific system design and operational requirements.