post column derivatisation with ortho-phthal-dialdehyde and fluorescence detection
NP-HPLC is "Normal Phase" HPLC, wherein the solvents used are less polar than the substrate in the HPLC column (e.g. using hexane or dichloromethane with a silica HPLC column). RP-HPLC is "Reverse-Phase" HPLC, wherein the solvents used are more polar than the substrate in the HPLC column (e.g. using Water and Methanol with a octadecylsilane (ODS or C18) column).
To read an HPLC chromatogram effectively, start by identifying the peaks representing different compounds. Analyze the peak shapes, heights, and retention times to determine the compounds present. Compare the chromatogram to a standard or reference for accurate identification. Pay attention to any abnormalities or unexpected peaks that may indicate issues with the analysis.
A histamine chamber is used to test for histamine sensitivity or allergies by exposing the individual to controlled levels of histamine and observing their reaction. This type of test can help diagnose conditions like histamine intolerance or allergies.
Normal phase HPLC separates compounds based on their polarity, with the stationary phase being polar and the mobile phase being nonpolar. Reverse phase HPLC separates compounds based on their hydrophobicity, with the stationary phase being nonpolar and the mobile phase being polar. Normal phase HPLC is typically used for separating polar compounds, while reverse phase HPLC is used for separating nonpolar compounds.
Histamine is produced by the body in response to allergens, and antihistamine drugs work by blocking the action of histamine in the body.
In an HPLC column one can see very small molecules such as ATP, histidine, glucose, uracil, and pyridine. It is a form high quality of liquid Chromatography.
NP-HPLC is "Normal Phase" HPLC, wherein the solvents used are less polar than the substrate in the HPLC column (e.g. using hexane or dichloromethane with a silica HPLC column). RP-HPLC is "Reverse-Phase" HPLC, wherein the solvents used are more polar than the substrate in the HPLC column (e.g. using Water and Methanol with a octadecylsilane (ODS or C18) column).
Histamine and heparin
why RT was shifting & how to RT calculation in HPLC
no it is the basophils that produce histamine
To read an HPLC chromatogram effectively, start by identifying the peaks representing different compounds. Analyze the peak shapes, heights, and retention times to determine the compounds present. Compare the chromatogram to a standard or reference for accurate identification. Pay attention to any abnormalities or unexpected peaks that may indicate issues with the analysis.
A histamine chamber is used to test for histamine sensitivity or allergies by exposing the individual to controlled levels of histamine and observing their reaction. This type of test can help diagnose conditions like histamine intolerance or allergies.
histamine
Basophils are the granulocytes that produce and release histamine. Histamine is involved in the inflammatory response and allergic reactions.
mixture of enantiomers can be separated by HPLC
"RS-HPLC method" means "Related Substance HPLC Method".
Histamine Chamber is a scientific instrument use to evaluate antiasthmatic activity of certain drugs/chemicals in lab. animals. The Lab. animals are exposed to histamine aerosol in the Histamine Chamber.