answersLogoWhite

0

The two indirect methods of titration are back titration and reverse titration. In back titration, an excess of a reagent is added to react with the analyte, and then the unreacted excess is titrated to determine the amount that reacted with the analyte. In reverse titration, a standard solution is first added to a known amount of analyte to react completely, and then the excess standard solution is titrated back to determine the amount that reacted with the analyte.

User Avatar

AnswerBot

1y ago

What else can I help you with?

Continue Learning about Chemistry

What is indirect titration?

In indirect titration, a substance that reacts with the analyte is added first, and then the excess of this substance is titrated with another reagent to determine the amount used. This method is useful when the analyte does not directly react with the titrant.


What are complexometric titration method?

Complexometric titration is a type of volumetric analysis used to determine the concentration of metal ions in a solution by forming complexes with a specific reagent. In this method, a chelating agent is typically used to form a stable complex with the metal ion, and the endpoint of the titration is usually determined using a colorimetric indicator or a pH meter. This technique is commonly employed in the analysis of a variety of metal ions in solution.


Why iodometic titration is better than iodimetric titration?

Iodometric titration is better than iodimetric titration for the determination of reducing agents, as it directly measures the amount of oxidizing agent present. This method is more precise, as it involves the direct reduction of a known quantity of iodine to iodide ion. It is also less prone to interference from side reactions compared to the indirect measurement in iodimetric titration.


What is double titration?

Double titration is a titration method used to determine the concentration of a solution by performing two successive titrations. In the first titration, a known concentration of a standard solution is used to titrate the unknown solution. In the second titration, a different standard solution is titrated with the excess volume from the first titration to determine its concentration.


Is titration of thiosulfate is a direct or indirect iodine titration?

Indirect http://books.google.co.uk/books?id=wxMrnl9Hy0AC&pg=PA131&lpg=PA131&dq=iodine+indicator+in+alkaline+environment&source=web&ots=wGSsDuMEy3&sig=TasdtQD2-vRoFyq7pKt4-VeQ7wk&hl=en&sa=X&oi=book_result&resnum=8&ct=result#PPA130,M1

Related Questions

What is indirect titration?

In indirect titration, a substance that reacts with the analyte is added first, and then the excess of this substance is titrated with another reagent to determine the amount used. This method is useful when the analyte does not directly react with the titrant.


What are complexometric titration method?

Complexometric titration is a type of volumetric analysis used to determine the concentration of metal ions in a solution by forming complexes with a specific reagent. In this method, a chelating agent is typically used to form a stable complex with the metal ion, and the endpoint of the titration is usually determined using a colorimetric indicator or a pH meter. This technique is commonly employed in the analysis of a variety of metal ions in solution.


Why iodometic titration is better than iodimetric titration?

Iodometric titration is better than iodimetric titration for the determination of reducing agents, as it directly measures the amount of oxidizing agent present. This method is more precise, as it involves the direct reduction of a known quantity of iodine to iodide ion. It is also less prone to interference from side reactions compared to the indirect measurement in iodimetric titration.


Methods of preparing statement of Cash flow?

Following are methods:1 - direct method2 - indirect method


What is double titration?

Double titration is a titration method used to determine the concentration of a solution by performing two successive titrations. In the first titration, a known concentration of a standard solution is used to titrate the unknown solution. In the second titration, a different standard solution is titrated with the excess volume from the first titration to determine its concentration.


Is titration of thiosulfate is a direct or indirect iodine titration?

Indirect http://books.google.co.uk/books?id=wxMrnl9Hy0AC&pg=PA131&lpg=PA131&dq=iodine+indicator+in+alkaline+environment&source=web&ots=wGSsDuMEy3&sig=TasdtQD2-vRoFyq7pKt4-VeQ7wk&hl=en&sa=X&oi=book_result&resnum=8&ct=result#PPA130,M1


Why the auscultatory method is called indirect?

The auscultatory method is called indirect cause it indirectly measures the arterial blood .


What is indirect method?

Indirect Planting-In this method of planting,the plants need to be transferred from a seed box to it's permanent place.


Why might the answers to the best tablet by the titration method and the best tablet by the FeCl3 method NOT agree?

The differences in results between the titration method and the FeCl3 method could be due to variations in the methods themselves. The titration method measures the amount of a specific substance through a chemical reaction, while the FeCl3 method detects a different property or compound in the tablet. Additionally, the precision and sensitivity of each method may differ, leading to discrepancies in the results obtained.


What is a double burette method?

The double burette method is a technique used in titrations to accurately measure the volume of liquid dispensed during the titration process. It involves using two burettes - one to dispense the titrant and another to collect the solution being titrated. This method allows for precise control and measurement of the volumes of liquids involved in the titration.


Why tartaric assay method falls under alkalimetric direct titration method?

The tartaric assay method falls under the alkalimetric direct titration method because it involves the direct titration of tartaric acid with a standardized alkali solution to determine its concentration. The method is based on the neutralization reaction between the tartaric acid and the alkali, which allows for the quantitative determination of the tartaric acid content present in the sample.


What is indirect method planting?

Indirect Planting-In this method of planting,the plants need to be transferred from a seed box to it's permanent place.