Oxylene is used as an internal standard in experiments because it absorbs a wide area. It also absorbs other compounds easily.
It is primary standard is a substance that has a known high digree of purity ,reatively large molar mass ,is nonhygroscopic and reacts in a predic table way.
Ernest Rutherford used the gold foil experiment in 1908 .
In order to know what the dissolving medium used in an experiment one would need to know more information in regard to the experiment.
A titration experiment or procedure uses a reactant to find the quantity of a particular substance dissolved in a solution. The reactant is added slowly and a color change occurs and disappears when stirred. The end point is found when the slightest hint of color remains. The amount of reactant used is measured and used to calculate the concentration of the substance being tested for.
it is used as an acid-base indicator
the control
The control is the standard used to compare with the experimental results.
That would be the control....i think....:)
Internal standard can be used for calibration by plotting the ratio of the analyte signal to the internal standard signal as a function of the analyte concentration of the standards. This is done to correct for the loss of analyte during sample preparation or sample inlet.
Standard error is the difference between a researcher's actual findings and their expected findings. Standard error measures the accuracy of one's predictions. Standard deviation is the difference between the results of one's experiment as compared with other results within that experiment. Standard deviation is used to measure the consistency of one's experiment.
The standard for comparison in a experiment is known as a control variable. This is useful to any experiment and serves as a reference point used to draw conclusions.
Constants are factors in an experiment that stay the same. This should not be confused with controls -- which is a standard used for comparison
Control
It is primary standard is a substance that has a known high digree of purity ,reatively large molar mass ,is nonhygroscopic and reacts in a predic table way.
Internal Standard(IS) is similar in structure and chemical properties to the analyte of interest. We add equal amount of IS to all samples including blank and used to calculate the analyte loss while preparing the sample. IS used for calibration by plotting the ratio of analyte signal to the IS signal.
Internal standard is primarily used to increase the accuracy and precision of analytical methods that have large inherent variability. The method is used in chromatography (GC, HPLC) where a compound similar to the analyte of interest is added to the sample and run. By having the analyte and the standard elute in the same run, the run to run variability is eliminated giving more precise results. Obviously one needs to calibrate the responses of the internal standard with that of the analyte. Incidental benefits are saving time and money by having less runs. Hope this is useful. Jay, Winnipeg, Canada
A potato is used in the osmosis experiment.