If its just the compressor that's not starting then it could be

bad contactor

bad capacitor

burnt or broken wire

bad compressor

lower than normal line voltage

If you are not comfortable testing or working with electricity then don't attempt this on your own

User Avatar

Wiki User

14y ago

What else can I help you with?

Related Questions

How do you reset a goodman compressor?

Any compressor has an internal overload which may go off due to bad condenser fan motor, clogged condenser, restriction of air, the only way to test is to check the condinuity between terminal common start and run if common open shut off system and allow 24 hours to reset if it doesn't reset may need new compressor


At what age did Billie Holiday start to sing?

Benny Goodman


What CSR on a compressor block stands for?

Different motor windings in the compressor: Common, Start, Run


Will a faulty capacitor cause compressor not to run?

Yes, a faulty capacitor can prevent a compressor from running. The capacitor helps start the compressor by providing an initial boost of energy, and if it fails, the compressor may not receive the necessary power to start or operate efficiently. This can lead to the compressor either not running at all or struggling to start, potentially causing additional damage. It's essential to check and replace any faulty capacitors to ensure proper compressor function.


What is the function of Compressor Start relay?

the start relay helps the compressor start up then takes itself out of play when the compressor gets going. The older units will have a capacitor and a relay mounted in the control panel and the new ones are all in one...you just parallel the run capacitor.


Wiring diagram for copeland cr42k6 compressor?

The wiring diagram for a Copeland CR42K6 compressor typically includes connections for the power supply, start capacitor, run capacitor, and the compressor terminals (common, start, and run). It's crucial to refer to the specific model’s service manual for accurate wiring details, as variations can exist between models. Ensure to follow electrical safety standards and guidelines while working with the compressor's wiring to avoid damage or hazards. For precise connections, consult the manufacturer's documentation or a qualified technician.


How does a central air conditioner compressor act when the capacitor burns out?

the capacitor starts the compressor generally if it don t work the compressor usually won t start


What does it mean when our goodman furnace has a blinking light?

circuit board on goodman furnace blicking continously after try to start 3 times fire down led light


Servicing a stuck hermetic compressor?

To service a stuck Hermetic compressor,repair the start components of the air conditioning compressors.


How did Benny Goodman start playing clarinet?

He was enrolled in music lessons at age 10.


How do you install a start relay on the compressor terminals?

To install a start relay on the compressor terminals, first, ensure the power is turned off and the unit is unplugged for safety. Locate the compressor terminals, usually found on the compressor's side. Connect the start relay's terminals to the corresponding compressor terminals, typically matching the labeled connections (such as "C," "S," and "R"). Finally, secure the relay in place, double-checking all connections before restoring power to the unit.


Can a start capacitor blow out an air conditioner compressor?

Not likely