Yes, you can replace a 3-ton compressor with a 2.5-ton compressor, but it may lead to inadequate cooling for larger spaces or higher heat loads, as the new unit will have less capacity. It's essential to assess the specific cooling requirements of your system and ensure that the 2.5-ton compressor meets your needs. Additionally, you may need to adjust other components, such as the expansion valve or ductwork, to ensure optimal performance and efficiency. Consulting with an HVAC professional is advisable before making the change.
17amps
How many lra 1ton 3 phase compressor
The current rating in amperes (LRA) for a 3-ton air conditioner compressor typically ranges from 30 to 50 amps, depending on the specific model and manufacturer. The LRA value represents the maximum current drawn by the compressor at startup. It's essential to check the manufacturer's specifications or the compressor's nameplate for the exact LRA rating for a particular unit.
53189
acu compressor motor window type aircon 45 uf capacitor for 2.5 hp compressor 50 uf for 3 ton acu 60 uf for 1.5 hp compressor 35 uf
I'm not an air conditioning expert, but I would expect that the compressor will run a lot more than it needs to. A 2 ton coil will not cool as much air as a larger capacity 3 ton coil. Experts?
Installing a 3 1/2 ton condenser on a 3 tr evaporator will not function properly. There isn't enough evaporator coil surface area to absorb heat and vaporize refrigerant liquid for its return back to the condenser compressor. What can be done is a 3 ton condenser unit with a 3 1/2 evaporator coil.
Maybe. The coil is not matched to a 2 or 3 ton truck It is matched to the engine and igniton control system. So it may be the same part #.
Absolutely NOT ! you will end up with more problems,and spend more redoing it because it doesn't work together.And besides a 4 ton compressor needs a 4 ton condensor.3 ton condensor will not have the surface area to cool the freon from a hot vapor to a cool liquid,that is needed for optimal performance in air handler,which is also rated for a 4 ton ,due to the coil size and the expansion valve size.
No, it is not recommended to pair a 5 ton coil and furnace with a 3 ton compressor. The sizes need to be compatible for the system to operate efficiently and effectively. Mismatched components can lead to performance issues and potential damage to the system.
just the condensing unit roughly 1500to2000
If the coil in the air handler is 2.5 tons, yes. The system is mismatched and you may also experience compressor failures due to liquid refrigerant flooding back to the compressor due to the undersized evaporator coil.