Q: I am wiring a circuit in my shop to run a MIG welder that draws a max of 30 amps The run is approximately 40' from the service panel What gauge wire should be used for this circuit?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is the proper ampere rating of circuit breaker for electric arc welder?

The proper ampere rating of a circuit breaker for an electric arc welder depends on the arc welder. Each is different. Look at the nameplate on the arc welder and choose the circuit breaker and wiring accordingly.


What are the dimensions of a spot welder?

Spot welder dimensions may vary depending on the make or brand of welder. The average dimensions of a spot welder are approximately 170 x 460 x 350 mm.


What school should a welder go to?

A Welder should go to Harverd are the sort


Will a 20A 240V breaker be sufficient for a 240V 22A input welder or do you need to go to a 30A?

It would have to be a 30 amp breaker to use the full power of the welder. I'd say go with the 30A. The general rule is that your planned load should only be 80% of the circuit capacity. That means a 30A circuit should have a maximum load of of (30*0.8) = 24A. With the 30 amp breaker you must have at least #10 wires feeding the circuit.


What size circuit breaker is needed for a 190 amp welder?

The size of the circuit breaker and the wire that will feed the welder is based on the amperage that is needed by the welder. The voltage only explains what the insulation factor of the wire should be.As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.


Can you install two 220v receptacles for a welder in two different areas of your shop on the same circuit?

Technically no. In the USA the NFPA electrical code requires a separate circuit for each large appliance receptacle- there are a few exceptions (such as a heater and AC on same circuit) - I don't think the welder is one of the exceptions. In practice, as long as only one receptacle is used at a time, it will work fine Make sure that the wire size is correct for the current (amp) draw. This is taken off of the welder nameplate. Size the breaker to protect the wire size. If more that one welder gets plugged in the breaker will trip.


What size wire for a welding extension cord 220v 50 amps?

Wire size depends on amps. Use #10 for 30a. #8 for 40 or 50a. #6 for 60a.


Can you weld map welder id numbers?

probably a editing mistake; question should be: can you read map welder id numbers?


What is the principle of electric welding?

the basic principle of welding is 1. first we have some broken material 2. a welder 3. welder should know how to weld


What is the pay rate for experieced welder in NJ?

What is the yearly wage of a welder? What is the yearly wage of a welder? What is the yearly wage of a welder?


What is the 60 Hz on a welder with the listed input as 208 230 volt single phase 60Hz?

60 Hertz is the frequency that the welder should be connected to, to work as it is designed to.


If you have a spa that is 240V with 4 wires can you hook an extension cord from a 240V welder to it to see if it works if the cord only has three wires?

Well, maybe. What is the current rating on the spa circuit? What is the current rating on the welder? If the welder is larger than the outlet, then no. It must be the other way around. If the current ratings are OK, then yes. Your welder doesn't need 110V so it doesn't connext to neutral. Connect the hot leads to hot and ground to ground.