AVR stands for Automatic Voltage Regulator for generator. Most AVR work by automatically comparing the sensed voltage with the reference setting generator output voltage then diverting the input current to the exciter circuit. Some AVR circuit are configured in parallel connection with the exciter stator winding, When it sense below rated set voltage, more current is feed to the exciter to catch up the voltage difference until it would reach equilibrium again, when it is within rated voltage less current is feed to the exciter or more current is diverted to the AVR circuit. Some AVR has manual remote voltage trim or control to manually raise or lower the set voltage. The AVR works also during parallel operation by regulating voltage and controlling load Ampere (load sharing capability), the power factor (PF) and VAR (Volt-Amps Reactive).
AVR stands for automatic voltage regulator.
The function of AVR is to automatically regulate the voltage of Generators. As the terminal voltage of a generators drops the AVR boosts the voltage.
there is problem in AVR and magnetic strength.
The rated voltage of a generator decreases due to many causes such as armature reaction, overloading of the generator and AVR failure/ weak excitation voltage.
Automatic voltage regulator (AVR) : Depends on the generator output voltage & out put current/Kvar it will change the exciter voltage. Change in excitation voltage controls the reactive power (Kvar). whereas, a Governor controls the fuel supply to primemover(Engine) in order to control the speed of generator, change in speed (rpm) also controls Active power (KW).
isolate the avr unit,and,then,check,the ,phases,w.r.t. earth,and,make sure,that,the generator,is in dead condition,i,e,,it is not running.
The AVR (automatic voltage regulator) measures the generator voltage output and varies the field voltage (which varies the strength of the rotating magnetic field) to maintain a fixed output voltage. Some generators excite (power) the AVR and field windings from the main stator, some provide a separate stator winding just for field excitation, and others provide a separate stator winding and rotating permanent magnets (called PMG) for field excitation. The generators that do not have permanent magnets rely on residual magnetism for the initial voltage to start the system or may provide initial voltage from the engine's starting battery.
No, you cannot accurately measure the output voltage of an Automatic Voltage Regulator (AVR) using a DC meter, as the AVR typically regulates AC voltage for the generator. A DC meter is designed for measuring direct current voltage, while the voltage output from a generator is usually alternating current (AC). To measure the AC voltage effectively, you would need an AC voltmeter or a multimeter set to the AC voltage setting.
avr microcontroller can be burnt by using a burner with variety of softwares like AVR BURN O MAT....
SCM CT is a normal CT which is connected in two phase of the turbines & its terminals are connected to the AVR. Depending on the load on the turbine the current increases & accordingly it gives the input to the AVR so as to develop the required field to generate the same load without any dip in the voltage.