A fillet weld is a triangular weld with sides of a width, w by w . The throat is the thinnest portion, which is w divided by square root of 2. The throat thickness is used in stress calculations
Weld throat thickness is measured from the root of the weld to the face of the weld, specifically the shortest distance in a cross-section of the weld. This measurement is crucial for ensuring the weld meets design specifications and can be done using calipers or a weld gauge. For fillet welds, the throat thickness can also be calculated using the formula: throat thickness = 0.707 times the leg length of the weld. Accurate measurement is essential for assessing the strength and quality of the weld.
To calculate the number of welding rods needed for a fillet weld, first determine the weld size and length required. Use the formula for the volume of the weld, which is the weld size (throat thickness) multiplied by the length of the weld and the number of passes needed. Then, convert this volume into weight by considering the density of the welding rod material. Finally, divide the total weight of the weld metal by the weight of a single welding rod to find the number of rods required.
it depends on the fillet welds dimentions and fit up requirements
A fillet weld is the joint of 2 pieces of material, usually at a 90 degree angle. see http://www.unified-eng.com/scitech/weld/fillet.html
Leg of the weld. Fillet is the part you cut off e.g. a corner...
It depends on the thickness and type of materials being welded.
In a mitre fillet weld with equal leg lengths, the design throat thickness (T) is typically calculated as 0.707 times the leg length (L). Therefore, the ratio of leg length to throat thickness can be expressed as L/T = L/(0.707L) = 1.414. This means the leg length is approximately 1.414 times the design throat thickness.
wildly welding main pipe the are fillet weld or butweld
FP on a weld symbol stands for "Fillet weld all around." This means that a fillet weld is required to be made on all sides of the joint where the symbol is placed. The weld size, length, and other specifications should be indicated next to or below the FP symbol on the welding symbol to provide further guidance to the welder. It is important to follow the welding symbol precisely to ensure the weld meets the required specifications and standards.
A fillet weld in any single continuous weldmay underrun the nominal fillet weld size specified by2 mm [1/16 in] without correction, provided that theundersize portion of the weld does not exceed 10% of thelength of the weld. On the web-to-flange welds on girders,underrun shall be prohibited at the ends for a lengthequal to twice the width of the flange.
A fillet weld is the joint of 2 pieces of material, usually at a 90 degree angle. see http://www.unified-eng.com/scitech/weld/fillet.html