Fire alarm control panels are powered by the mains power. Commonly, the fire alarm will have a battery back up power in place so that the system still remains functional and powered up when the mains fails. When the mains is powering the panel, the batteries are charged fully so that when a power cut occurs, they have enough power to operate the system for a certain amount of time. Generally, in the UK, a panel is powered by 240 Volts and is stepped down by a transformer to 24 Volts. The panel will usually have two, 12 Volt batteries installed in the panel- they are reffered to as SLA's. (Sealed Lead Acid). These batteries though will only last for about a day or two.

Some systems are larger and have more power drain, so they may be required to have additional backup batteries connected and perhaps spares available on site. If the fire alarm system is non-operational, the local fire authorities may require a company to post a 24-hour "fire warden", in case of fire, with adequate training and equipment, or otherwise shutter the business until the alarm is working.

User Avatar

Wiki User

12y ago

What else can I help you with?

Related Questions

What is a fire alarm panel?

Mimic panel in fire alarm system 'mimics' or mirrors the signal of the Main Fire Control Panel.


How a mimic panel works in fire alarm system?

Mimic panel in fire alarm system 'mimics' or mirrors the signal of the Main Fire Control Panel.


How do you turn off a fire sprinkler tamper alarm?

First you locate the source of the alarm, undo the condition (e.g., valve closed, inadequate pressure, etc), then reset the alarm condition on the sprinkler control panel and reset the alarm on the fire alarm control panel (assuming they're connected, as required by many fire codes).


What is the use of repeater panel in fire alarm control panel?

Repeater panels, also known as Annunciator panels are used to provide a visual display of the main panel. They can additionally provide limited control functions, such as acknowledge, silence, and reseting the main fire alarm panel.


Why are use plate Repeater in the fire alarm system and Where to install?

Plate Repeater is used in the fire alarm system so that it shows the same information that the main control panel does. The repeater panel looks a lot like the main control panel and can be placed up to 30 meters from the main control panel.


What is the minium size branch circuit for a fire alarm system?

Are you referring to the circuit supplying power to the control panel or the initiation/notification branch circuits controlled by the fire alarm system? The ampacity of the fire alarm control panel would determine the circuit size of the branch circuit supplying power to the control panel and the terminal on the control panel and fire alarm device would detrmine the size of conductor that it will accept. Most fire alarm control panels would require a minimum 15 amp circuit. The minimum conductor size allowed per the NEC would be 14 AWG. 22 AWG. is the smallest conductor that most control panels and device terminals will accept. These are considered Power Limited circuits.


How can I effectively stop a fire alarm from sounding?

To effectively stop a fire alarm from sounding, locate the alarm's control panel and enter the designated code or press the reset button. If you are not able to do this, contact the fire department for assistance.


What type of fire alarm annunciation system identifies the zone in which the alarm was initiated both at the alarm control panel and through the audio notification device?

zoned


What is an alarm control panel?

An electronic unit which controls an alarm system. This could be an Intruder Alarm, Fire Alarm etc. They commonly power the alarm system, monitor the devices on the system and display the status of the alarm system. Such as if there are any faults or alarm activations. Most also have their own battery back up, just in case the mains power fails, they are still fully functional. A user can control what the panel does. For example, to test the alarms, programme, disconnect certain circuits etc.


What should I do if my fire alarm is beeping due to a low battery?

If your fire alarm is beeping due to a low battery, you should replace the battery immediately to ensure the alarm functions properly in case of a fire.


What should you do if your fire alarm is beeping due to a low battery?

If your fire alarm is beeping due to a low battery, you should replace the battery immediately to ensure the alarm functions properly in case of a fire.


What is the maximum number of devices can be connected in one loop of a fire alarm control panel?

There is no such standard. Fire alarm control panels are typically customized for as many loops as necessary for the structure. It may have one loop or a hundred or anything in between.