answersLogoWhite

0

A Class-A zone differs from a standard Class-B zone in that it does not use an EOL resistor at the end of the zone. Instead, the zone is looped back into Class-A input terminals on the circuit. Class-A must first be programmed on the panel for it to be used, and it is not available on all panels.

User Avatar

Wiki User

14y ago

What else can I help you with?

Related Questions

Compare class E fire alarm system with individually coded fire alarm system.?

Because it is for LIFE SAFETY.


What is a class E fire alarm system?

Oh, dude, a class E fire alarm system? That's like the unicorn of fire alarms. It doesn't actually exist! You might be thinking of Class A, B, C, D, or K fire alarm systems, but definitely not Class E. So, unless you're in a parallel universe where Class E fire alarms are a thing, I'd say it's time to double-check that question.


What is the difference between a Class A and Class E fire alarm system?

A Class A fire alarm system is designed to provide a continuous path for alarm signals, meaning that if one circuit fails, the other can still transmit alarms. In contrast, a Class E system uses a more complex signaling method, often with a combination of circuits, allowing for multiple paths and enhanced reliability, but it may not provide the same redundancy as Class A. Essentially, Class A prioritizes simple redundancy, while Class E focuses on advanced signaling techniques.


How a mimic panel works in fire alarm system?

Mimic panel in fire alarm system 'mimics' or mirrors the signal of the Main Fire Control Panel.


Notify Every Person About a Fire with a Notifier Fire Alarm System?

Commercial businesses, schools, colleges, hospitals and medical clinics need Notifier fire alarm systems. An excellent Notifier fire alarm system can save lives when there is a sudden fire. Fires spread throughout a building quickly, and a Notifier fire alarm system can alert everyone in the building before the fire is too dangerous for any chance of escape. Every commercial building needs protection from an unexpected fire, and a Notifier fire alarm system notifies every person that there is an ensuing fire. The positive results that stem from installing a Notifier fire alarm system make it worth your while to inquire about this excellent fire alarm system today.


Fire Alarm system OF USES?

To alert to warn people of an emergency and the need to quickly evacuate. Such as: -Fire -Bomb Alert -Dangerous Chemical Spill -Gas leak -Someone/something dangerous to get away from. Some fire alarm systems are also used as signals for different things. For example, used for class change in schools, the fire alarm is used to sound for a couple of seconds to signal the change over of class. Fire alarm components such as sirens and bells can be used for different applications. Such as train warning for a train barrior closing, Intruder Alarm, Lift Alarm etc.


What is Edward fire alarm system?

Edwards Systems Technologies or EST is a fire alarm manufacturer and distributor.


What class is the eol in fire alarm system?

In a fire alarm system, the EOL (End of Line) resistor is typically used in Class B circuits. It is placed at the end of the circuit to monitor the integrity of the wiring and ensure that the system can detect faults such as short circuits or open circuits. The EOL resistor helps to maintain the proper functionality of the system by allowing it to detect whether the circuit is complete or compromised.


Design OF A fire fighting system for electrical control building?

we have to distinguish between firefighting and fire alarm system. fire fighting is mechanical work (either sprinkler system or Foam or CO2 or FM200) and there is fire alarm or detection system this is an electrical thing that includes ( detectors an fire alarm system) for electrical control building we use FM200.


What is a fire alarm panel?

Mimic panel in fire alarm system 'mimics' or mirrors the signal of the Main Fire Control Panel.


What auxiliary alarm system is wired directly to a municipal fire alarm box?

A "master box" connects an alarm system to the municipal alarm system.


What do I need to know about automatic fire alarm systems in rehabbing an old warehouse?

In terms of automatic fire alarm systems in rehabbing an old warehouse, you should activate the facility fire evacuation alarm system. Another thing you should know is make sure to have an automatic sprinkler system connected to the fire alarm system