Is 404a freon compatible with any other freon?

No.


Is R404A freon compatible with R409a?

No r404a is not compatible with r409a, r134a and 404a use the same lubricates and are compatible but r409a use a different lub making them incompatible


Will 404a mix or use the same system as r12?

R-404A is not compatible with R-12 systems due to differences in chemical composition and operating pressures. While R-404A is a hydrofluorocarbon (HFC) refrigerant, R-12 is a chlorofluorocarbon (CFC), and their properties require distinct system components. Converting an R-12 system to use R-404A typically involves replacing the compressor, expansion valve, and other components to ensure proper functionality and efficiency. Always consult a qualified technician for refrigerant conversions.


What is the property of refrigerant 404A?

what is suction pressure of r407a


Can R22 be used with 404A refrigerant?

No, refrigerants cannot be blended.


What should the sub cooling be on a txv 404a refrigerant freezer?

42


Could you mix 404a refrigerant with R12?

Mixing 404A refrigerant with R12 is not recommended, as they are incompatible and can lead to system damage, decreased efficiency, and safety hazards. R12 is a CFC refrigerant, while 404A is a blend of HFCs that operates at different pressures and thermodynamic properties. Additionally, mixing refrigerants can complicate recovery and recycling processes, making it difficult to maintain compliance with environmental regulations. It's best to use the specified refrigerant for your system.


What is the low side pressure of a freezer using R 404A refrigerant?

if room tem is 70f 15psi


What is the low side pressure of a freezer using R-404A refrigerant?

if room tem is 70f 15psi


What is high side and low side pressures of R-404A in an ice machine?

The high side pressure for R-404A in an ice machine is typically around 250-300 psi, while the low side pressure is usually around 40-50 psi. These values can vary depending on factors such as the ambient temperature and the ice machine's operating conditions.


Mixing freon 22 with 404A would it work?

No, mixing refrigerants like Freon 22 (R-22) and 404A is not recommended as it can create issues with system performance, efficiency, and potentially damage the equipment. It is important to use the correct refrigerant specified by the equipment manufacturer to ensure proper operation and avoid any safety concerns.


What is the correct suction pressure when charging a true freezer using refrigerant 404a?

frezer not frezing hi side 250 psi low side 45 psi