A low pressure steam boiler has a maximum allowable working pressure of up to?

The maximum allowable working pressure for a low pressure steam boiler is typically up to 15 psi (pounds per square inch). This indicates the highest pressure level at which the boiler can operate safely without the risk of failure or damage. It is important to adhere to the manufacturer's specified limits to maintain the boiler's safety and functionality.


How do the weather conditions in high air pressure situations compare to those in low air pressure situations?

In high air pressure situations, the weather is usually calm and clear with little to no precipitation. In low air pressure situations, the weather is often stormy with clouds, rain, and strong winds.


How do you calibrate compound gauges?

To calibrate compound gauges, you will need a calibration pump and a pressure calibrator. Connect the compound gauge to the calibration pump and apply pressure using the pressure calibrator. Compare the readings on the compound gauge with the readings on the pressure calibrator and make necessary adjustments to bring them into alignment.


Can mean effective pressure less than atmospheric pressure?

no Because any body subject is affected by the atmospheric pressure in the case of its occurrence under the pressure of what it means that the pressure for increased atmospheric pressure.


What is the water pressure as it exits into the air?

The water pressure decreases as it exits into the air due to the change in environment from a confined space to open air. The pressure depends on factors such as the speed of the water flow, height of the exit point, and the design of the exit nozzle.

Related Questions

What are your design strengths weaknesses?

There are many strengths and weaknesses a person could have in design. Someone may be able to sketch a vision perfectly but not be able to actually make it happen for example.


What is difference between design pressure and working pressure?

The working pressure is also referred to as the Maximum Operating Pressure (MOP). The MOP is the highest pressure expected during operation. The Maximum Design Pressure (MDP) includes the maximum pressure that is protected by relief valves in case of failure. For example, if the MOP is 100 psi and their are relief valves set at 10% above the MOP the MDP would be 110 psi.


Design a 66 inches dia buried pipe with working pressure 76 psi?

The pressure is important but so is the substance which the pipe is to carry. Is the substance carried at 76 psi or is that the external pressure


How do you convert a hydro test pressure to a pneumatic test pressure?

Design pressure multiply by 1.1 equal pneumatic test pressure. Design pressure multiply by 1.5 equal Hydrotest Pressure Note: Design Pressure is different from Operating pressure. Design Pressure is equal to Maximum Operating Pressure From: galdo.gaspar@ymail.com


How do you convert a pneumatic test pressure to a hydro test pressure?

Design pressure multiply by 1.1 equal pneumatic test pressure. Design pressure multiply by 1.5 equal Hydrotest Pressure Note: Design Pressure is different from Operating pressure. Design Pressure is equal to Maximum Operating Pressure From: galdo.gaspar@ymail.com


What is design pressure of LPG?

Design Pressure of LPG is nominally taken as 250Psi/1.725bar


What is the difference between Allowable Stress Design and Working Stress Design?

allowable stress design-2/3rd of yield working stress design is process yield


Why use working stress method for water tank design?

i think , because water tanks are more vulnerable structures and plus the tank is sometime overfilled and sometime empty, the pressure inside is so varying, its needs more safety precautions and as we all know working stress method assumes more safety factor than limit state design, which is an economical design, we prefer to use working stress method...


Compare differences in design strategies for developing an initial layout design for a new facility and for developing a revised layout design?

do u know the answer


What is unit of differential pressure?

Let me differentiate first between design pressure and mechanical design pressure. Design (or discharge) pressure is the pressure at the outlet of the pump, the pressure you've designed the pump to deliver. The mechanical design pressure is a value that the pump casing and downstream piping have to be able to withstand as a minimum*. I presume you mean design pressure as discharge pressure. In this case, differential pressure is the difference between the discharge pressure and the suction pressure (the pressure at the inlet of the pump**). * this is calculated taking into account that a pump would be working against a 'blocked discharge' or a closed valve in the outlet piping ** imagine a reservoir filled with liquid


What can you compare peer pressure or contrast with?

You can compare peer pressure with societal expectations in terms of external influences impacting behavior. You can contrast peer pressure with individual motivation by focusing on internal versus external factors driving decision-making.


Compare air pressure on earth to air pressure on the moon?

The moon has no air pressure because the moon has no air.