STOP! DON'T EVEN THINK OF DOING THIS!

It is foolish, dangerous and probably illegal to "hook up a 30 Amp breaker" into a 20 Amp wiring circuit feeding a 20 Amp socket outlet.

Leave the present 20 Amp circuit alone!

Someone who knows what he or she is doing must run a new30 Amp circuit with the correct type of socket outlet , the correct size of wiring and the correct size of circuit breaker to provide a safe and legal supply for your 30 Amp Air Conditioner unit.

<> <> <>

If you asked this question because you have no experience of working on the latest household power circuits and you hope to get enough information on this site to be able to do the job properly and safely, it is best to warn you not to rely on getting accurate information from this site about such a potentially dangerous subject.

By asking this question you probably aren't quite ready to take on this particular task.

Really, don't do this one yourself. Electricity is far too dangerous to handle if you don't already know your local Wiring Codes or Regulations or you have not been trained how to do this work.

How to do this job depends entirely on the Wiring Codes or Regulations for the locality (Town/State) and on the exact location of the appliance you wish to hook up. If it is anywhere that is subject to water splashes or spray - such as in any room supplied with running water pipes, like a kitchen, bathroom, shower room, etc., or in a pool-side area - in many places nowadays it is actually illegal to attempt to do this kind of work unless you are already a licensed electrician.

For your safety and that of anyone else who may to use the appliance, ask a professional licensed electrician to advise you or to do the work for you.

ALWAYS CHECK WITH YOUR LOCAL WIRING SAFETY OFFICE BEFORE YOU ATTEMPT TO CHANGE ANYTHING ON POWER MAINS OUTLETS

IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB

SAFELY AND COMPETENTLY

REFER THIS WORK TO QUALIFIED PROFESSIONALS.

If you do this work yourself, always turn off the power

at the breaker box/fuse panel BEFORE you attempt to do any work

AND

always use an electricians test meter having metal-tipped probes

(not a simple proximity voltage indicator)

to insure the circuit is, in fact, de-energized.

User Avatar

Wiki User

16y ago

What else can I help you with?

Continue Learning about Electrical Engineering

Can I wire nut two black wires together and hook 1 to a breaker?

Not according to the electrical code. It requires each separate circuit to be fed individually from its own breaker. If allowed it would reduce the total capacity of each circuit from one amp per outlet to a half amp per outlet if the circuit was fully loaded.The work around in situations like this is to use a tandem breaker which gives you the capacity of two complete circuits and only using one breaker slot in the distribution panel board.


What kind of breaker would you use for a 220 hook up?

In North America a two pole breaker will be used in the distribution panel for a supply of 240 volts for a 240 volt load.


Why not hook ground to neutral since they are hooked on same spot in breaker box why not in outlet box.?

The "hot" wire and the neutral wire both carry current (the same amount, in fact) when a load is connected to complete the circuit. The ground wire never carries current except when a fault-to-ground situation occurs. Yes, neutral and ground wires should both be at ground potential, but NO they should not be connected at the outlet.


How do you add an outlet to a porch light?

how do you hook up an outlet to a pull chain light without the outlet shutting off when you pull string


Can you take a 14 awg wire and hook it to a 12 awg wire?

Yes as long as the breaker feeding the circuit is protected with a 15 amp breaker. The code states that the over current device can be no smaller than that of the smallest current carrying conductor. That will be the #14 wire with a capacity of 15 amps.

Related Questions

How can I hook up an electrical outlet safely and correctly?

To safely and correctly hook up an electrical outlet, first turn off the power at the circuit breaker. Remove the cover plate and old outlet. Connect the wires to the new outlet following the manufacturer's instructions and using wire nuts. Secure the outlet in place and replace the cover plate. Turn the power back on and test the outlet to ensure it is working properly.


How can I properly hook up a GFI (Ground Fault Circuit Interrupter) outlet?

To properly hook up a GFI outlet, first turn off the power to the circuit at the breaker box. Remove the old outlet and connect the wires to the corresponding terminals on the GFI outlet (line and load). Make sure to connect the ground wire as well. Secure the outlet in place and turn the power back on to test the GFI functionality.


How can I learn how to hook up an outlet correctly?

To learn how to hook up an outlet correctly, you can follow these steps: Turn off the power to the outlet at the circuit breaker. Remove the cover plate and outlet from the electrical box. Connect the black wire to the brass screw, the white wire to the silver screw, and the green or bare wire to the green screw. Secure the wires in place and carefully place the outlet back into the electrical box. Screw the outlet into place and replace the cover plate. Turn the power back on and test the outlet to ensure it is working properly.


Can you hook up a two pole 20 amp breaker to a 30 amp outlet for a dryer?

Probably not. If the appliance has multiple heating levels then you might get away with it. In this scenario you would only be able to use 30 amps of the appliance's 40 amp capacity before the breaker would trip.


If your outlet is a 3 prong outlet can you hook up a 3 prong plug from your old stove to a new stove which has a 4 prong plug?

No you can not you will need to replace the plug with a 4 prong the same as the style of your oven and change your breaker to the correct Amp for your style of 4 prong plug


How do you hook up a GFCI outlet?

To hook up a GFCI outlet, first turn off the power to the circuit. Remove the old outlet and connect the wires to the corresponding terminals on the GFCI outlet (line and load). Make sure to connect the ground wire as well. Secure the outlet in place and turn the power back on to test the outlet.


How do I properly hook up an electric stove?

To properly hook up an electric stove, first make sure the power is turned off at the circuit breaker. Then, connect the stove's power cord to the outlet, ensuring it matches the voltage and amperage requirements. Finally, secure the stove in place and test it to ensure it is working correctly.


How to hook up a GFCI outlet?

To hook up a GFCI outlet, first turn off the power to the circuit. Remove the old outlet and disconnect the wires. Connect the line wires to the line terminals on the GFCI outlet and the load wires to the load terminals. Make sure to connect the ground wire as well. Secure the outlet in place and turn the power back on to test the outlet.


How do I properly perform the electric stove hook up in my kitchen?

To properly perform the electric stove hook up in your kitchen, follow these steps: Turn off the power to the kitchen at the circuit breaker. Remove the old stove and unplug it from the outlet. Install a new 240-volt outlet if needed, following electrical codes. Connect the wires from the outlet to the stove, matching the colors. Secure the connections with wire nuts and electrical tape. Plug in the stove and push it into place. Turn on the power at the circuit breaker and test the stove to ensure it is working properly. It is recommended to consult a professional electrician for assistance with this task to ensure safety and compliance with local regulations.


Would it be a problem to make a twist lock extension cord and hook it to a 30amp twist lock plug on a dedicated circuit for a tanning bed?

Get naked and all will be well


How can I safely and effectively hook up an outlet in my home?

To safely and effectively hook up an outlet in your home, follow these steps: Turn off the power to the circuit you will be working on at the breaker box. Use a voltage tester to ensure the power is off before proceeding. Remove the cover plate and existing outlet from the electrical box. Connect the black (hot) wire to the brass screw, the white (neutral) wire to the silver screw, and the green or bare wire to the green screw on the new outlet. Secure the outlet in the electrical box and replace the cover plate. Turn the power back on and test the outlet to ensure it is working properly. It is recommended to consult a licensed electrician if you are unsure or uncomfortable with performing electrical work.


Can you hook up a 4800 watt construction heater to a 40 amp stove outlet?

If you are using typical residential voltages ( 120v/240v) a 40 amp breaker is plenty big enough. You could even use a twenty amp breaker.